background image

1

Copyright  © 1999 Tripp Lite.  All rights reserved.

1111 W. 35th Street

Chicago, IL  60609 USA

Customer Support: (773) 869-1234

www.tripplite.com

Quick Installation:

p. 3

Basic Operation:

p. 4 - 5

Storage & Service:

p. 5

Specifications:

p. 6

Safety:

p. 2

Warranty & Insurance:

p. 6

Owner's Manual

TE SERIES

Standby UPS Systems (120V)

ESPAÑOL: p. 7-11

FRANÇAIS: p. 12-16

Summary of Contents for TE-300

Page 1: ...Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Quick Installation p 3 Basic Operation p 4 5 Storage Service p 5 Specifications p 6 Safety p 2 Warranty Insurance p 6 Owner s Manual TE SERIES Standby UPS Systems 120V ESPAÑOL p 7 11 FRANÇAIS p 12 16 ...

Page 2: ...unction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceabl...

Page 3: ...tallation program appropri ate for your operating system OPTION2 BrownoutVoltageAdjustment Adjust the Voltage Potentiometer UPS back panel clockwise to lower the voltage point at which the UPS switches from on line to battery output Your UPS will function properly without these connections or settings For users who experience frequent severe brownouts to avoid excessive battery drain Note Use caut...

Page 4: ...ted equipment Test your UPS s battery charge Leave your connected equipment ON With your UPS plugged in and turned ON move this switch to the left hold it there for 2 seconds and release it The UPS will momentarily switch to battery to test its charge If the UPS alarm sounds or the properly sized load is not supported let your UPS charge its batteries for 12 hours and repeat the test If alarm stil...

Page 5: ...hut down signal from the connected computer to conserve the UPS battery charge Contact Tripp Lite Customer Support for more information Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON This green light will turn ON whenever your UPS is plugged in and receiving normal AC line power This red light will turn ON when your UPS is providing...

Page 6: ...E 700L Output Capacity VA Watts 300 200 700 450 Battery Runtime Half Load Full Load Minutes 86 37 83 35 Battery Recharge Time 2 4 hrs 2 4 hrs Approvals UL cUL NOM UL cUL NOM Modem Fax Protection starts at 260V 1 line ALLMODELS InputVoltage Frequency 120V 60Hz OnBatteryOutputVoltageRange 120V 5 OutputWaveformLineMode filteredsine wave OutputWaveformBatteryMode PWMsinewave ACSurgeSuppression exceeds...

Reviews: