AVRX550U

3

Features

A

  ON/OFF/TEST BUTTON 

•   To Turn the UPS ON: Press and hold the ON/OFF/TEST Button for one second.* If utility power is absent, pressing the button will “cold-

start” the UPS, i.e. turn it on and supply power from its batteries.**

•   To Turn the UPS OFF: Press and hold the ON/OFF/TEST switch for one second.* The UPS will be turned completely off (deactivated).
•   To Run a Self-Test: With your UPS plugged in and turned ON, press and hold the ON/OFF/TEST button for three seconds.
CAUTION! To perform a self-test, you must hold the ON/OFF/TEST button continuously for three seconds. If you release the button too early, 
you will turn the UPS system OFF and cut power to connected equipment loads. To ensure you hold the button for the correct length of time, do 
not release the button until you hear the UPS System’s audible alarm beep twice. The first beep occurs after one second and indicates that the 
UPS will turn OFF if the button is released. The second beep occurs after three seconds and indicates that the UPS will perform a self-test if the 
button is released.

The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and charge. All LEDs will be lit and the UPS 
alarm will sound. See LED descriptions below to determine the results of the self-test.

Note: You can leave connected equipment on during a self-test.
CAUTION! Do not unplug your UPS to test its batteries. This will remove safe electrical grounding and may introduce a damaging surge into 
your network connections.

*The alarm will beep once briefly after one second has passed. **If fully charged.

B

  “ON/OFF” LED 

This green LED lights continuously to indicate that the UPS is ON and supplying your equipment with AC power either from a utility source 
or from the UPS’s internal batteries. If the UPS’s alarm is sounding (4 short beeps followed by a pause), the UPS is operating from its internal 
batteries.

C

  “OVERLOAD/CHECK BATTERY” LED 

This red LED lights continuously after a self-test to indicate the capacity of the outlets has been exceeded. To clear the overload, unplug some 
of your equipment from the outlets; then use the ON/OFF/TEST button to run a self-test. If the UPS continues to detect an overload, remove 
more equipment and repeat the self-test until successful. CAUTION! Any overload that is not corrected by the user immediately following a 
self-test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout. The LED flashes to indicate 
the battery needs to be recharged or replaced. If the LED flashes (and a continuous alarm sounds) during a prolonged blackout or brownout, the 
UPS’s batteries are nearly out of power; you should save files and shut down your equipment immediately. If the LED flashes following a UPS 
self-test (after the UPS is turned ON), it may indicate that the battery needs to be replaced. Allow the UPS to recharge continuously for 12 hours; 
then use the ON/OFF/TEST button to run a self test. If the LED continues to flash, contact Tripp Lite for service.   Should your UPS require 
battery replacement, visit Tripp Lite on the Web at www.tripplite.com to locate the specific replacement battery for your UPS.

D

  AUTOMATIC VOLTAGE REGULATION (internal) 

Automatically adjusts fluctuations to incoming voltage (under/over voltages) to supply connected equipment with 230V computer-grade output 
power. Automatic voltage regulation functions separately from battery power (will not drain battery).

E

  BATTERY, SURGE AND NOISE PROTECTED OUTLETS 

Provide both battery backup and surge protection. Plug your computer, monitor and other critical equipment into these outlets. NOTE: DO NOT 
PLUG LASER PRINTERS INTO THESE OUTLETS.

Summary of Contents for UPS System AVRX550U

Page 1: ...ile applications 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2010 Tripp Lite All rights reserved Important Saftey Instructions 2 Features 3 Installation 4 Optional Installation 5 Troubleshooting 5 Storage Service 6 Español 7 Français 13 ...

Page 2: ...quipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide Do not connect surge suppressors or extension cords to the output of UPS This might damage the UPS and may affect the surge suppre...

Page 3: ...r from a utility source or from the UPS s internal batteries If the UPS s alarm is sounding 4 short beeps followed by a pause the UPS is operating from its internal batteries C OVERLOAD CHECK BATTERY LED This red LED lights continuously after a self test to indicate the capacity of the outlets has been exceeded To clear the overload unplug some of your equipment from the outlets then use the ON OF...

Page 4: ...need to be turned back on I TEL DSL PROTECTION JACKS Stop surges on the phone or fax line Connecting your equipment to these jacks is optional Your UPS will work properly without this connection J GROUND CONNECTION Use this to connect any equipment that requires a chassis ground K BATTERY REPLACEMENT DOOR bottom panel not shown Under normal conditions the original battery in your UPS will last sev...

Page 5: ...ection is optional The UPS will work properly without this connection 2 Telephone DSL Protection Jacks Your UPS has jacks that protect against surges over a telephone DSL line Using telephone data cables connect your wall jack to the UPS jack marked IN Connect your equipment to the UPS jack marked OUT Make sure the equipment you connect to the UPS system s jacks is also protected against surges on...

Page 6: ...ons will be emailed to you Any damages direct indirect special or consequential to the product incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Products shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the product is within its...

Page 7: ... 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2010 Tripp Lite Todos los derechos reservados Instrucciones de seguridad importantes 8 Características 9 Instalación 10 Instalación opcional 11 Resolución de problemas 11 Almacenamiento y mantenimiento 12 English 1 Français 13 ...

Page 8: ...o artificial de la vida donde se puede esperar razonablemente que su falla cause la falla del equipo de mantenimiento de la vida o que afecte de manera importante su seguridad o eficiencia No use este equipo en presencia de mezclas anestésicas inflamables con aire oxígeno u óxido nitroso No conecte supresores de sobretensiones o cables de extensión al tomacorriente del UPS Esto puede dañar el UPS ...

Page 9: ...a para indicar que el UPS está encendido y suministrando energía CA a los equipos ya sea de una fuente de red de energía pública o de las baterías internas del UPS Si está sonando la alarma del UPS 4 pitidos cortos seguidos de una pausa el UPS está funcionando con las baterías internas C LED DE SOBRECARGA COMPROBACIÓN DE LA BATERÍA Este LED rojo se ilumina en forma continua después de un autotest ...

Page 10: ... cerca del puerto USB el UPS se apagará automáticamente En el caso de que se apague deberá volver a encender el UPS I CONECTORES DE PROTECCIÓN TELEFÓNICA DSL Detiene las sobretensiones en la línea telefónica o de fax La conexión de los equipos a estos conectores es opcional El UPS funcionará correctamente sin esta conexión J CONEXIÓN A TIERRA Utilícelo para conectar los equipos que requieren conex...

Page 11: ... 2 Conectores de protección telefónica DSL El UPS cuenta con conectores que protegen contra sobretensiones de la línea telefónica DSL Mediante el uso de los cables de datos telefónicos conecte el conector de la pared al conector del UPS marcado como ENTRADA Conecte el equipo al conector del UPS marcado como SALIDA Asegúrese de que el equipo al que conecta los conectores del sistema de UPS también ...

Page 12: ...le enviarán por correo electrónico Esta garantía no cubre ningún daño directo indirecto especial o consecuencial que el producto sufra durante el envío a Tripp Lite o un centro de servicio autorizado por Tripp Lite Los productos que se envían a Tripp Lite o un centro de servicio autorizado por Tripp Lite deben tener prepagos los cargos de envío Escriba el número RMA en el exterior del paquete Si e...

Page 13: ...ications mobiles 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2010 Tripp Lite Tous droits réservés Consignes importantes de sécurité 14 Caractéristiques 15 Installation 16 Installation facultative 17 Dépannage 17 Rangement entretien 18 English 1 Español 7 ...

Page 14: ...s applications où la défaillance de cet équipement peut éventuellement provoquer la panne de l équipement de survie ou altérer notablement sa sécurité ou son efficacité Ne pas utiliser cet équipement en présence d un mélange anesthésique inflammable avec l air l oxygène ou l oxyde nitreux Ne pas raccorder de suppresseurs de surtension ou de rallonges électriques à la sortie de l ASI Cela pourrait ...

Page 15: ... Ce voyant vert s allume en permanence pour indiquer que l onduleur est en marche et fournit du courant alternatif à votre équipement soit depuis une source d utilité ou depuis les batteries internes de l onduleur Si l alarme de l ASI sonne 4 bips courts suivis d une pause l ASI fonctionne sur batteries internes C DEL SURCHARGE VERIFIER BATTERIE Ce voyant rouge s allume en permanence après un auto...

Page 16: ...r automatiquement En cas d arrêt l onduleur devra être remis en marche I PRISES JACK DE PROTECTION TEL DSL Stoppe les surtensions sur la ligne du téléphone ou du fax Raccorder vos équipements à ces prises est facultatif L ASI fonctionnera correctement sans ce raccordement J RACCORDEMENT A LA TERRE Utilisez cette option pour connecter n importe quel équipement dont le boitier nécessite d être racco...

Page 17: ...lement sans ce branchement 2 Prises de protection des lignes téléphoniques DSL Votre ASI possède des prises qui offrent une protection contre les surtensions dans les lignes téléphoniques DSL En utilisant des câbles de données téléphoniques connectez votre prise murale à la prise de l ASI marquée IN Connectez votre équipement à la prise de l ASI marquée OUT Assurez vous que l équipement que vous c...

Page 18: ...de RMA ainsi que des instructions d expédition seront envoyés par e mail Les dommages directs indirects particuliers ou consécutifs au produit pendant le transport vers Tripp Lite ou vers un centre autorisé de Tripp Lite ne sont pas couverts par la garantie Les frais de transport des produits expédiés à Tripp Lite ou à un centre autorisé de Tripp Lite doivent être prépayés Inscrire le numéro RMA à...

Reviews: