8
CLEARING CLOGGED TIP
a) Release trigger, put safety ON.
b) Rotate T93R Tip so the arrow is poin�ng backwards.
c) Take safety OFF
d) Trigger gun to clear clog. Never point gun at your hand or in a rag!
RETURN TO SPRAY
a) Put Safety ON.
b) Return Tip to spray position.
c) Take safety OFF and continue spraying.
CLEAN UP
1. Turn power OFF and unplug sprayer.
2. Turn pressure to lowest se�ing. Trigger gun to relieve pressure.
3. Put prime hose in pail. Turn the prime / spray valve so the handle is poin�ng down.
4. Remove guard and T93R �p. Clean �p with soft bristle brush. DO NOT STORE IN WATER.
5. Remove suc�on hose from paint and place in flushing fluid. Use water for water base paint and mineral
spirits for oil base paint.
6. Plug in sprayer. Turn power ON. Turn the prime / spray valve so the handle is horizontal.
7. Hold gun against paint pail. Take trigger safety OFF. Trigger gun and increase pressure until flushing fluid
appears.
8. Move gun to flushing pail, hold gun against pail. Trigger gun to thoroughly flush system. Release trigger and
put trigger safety ON.
9. Turn the prime / spray valve so the handle is poin�ng down and allow flushing fluid to circulate for 1 to 2
minutes to clean prime hose.
10. Raise the suc�on hose just above the flushing fluid and run sprayer for 15 to 30 seconds to drain fluid.
Turn power off.
11. Close prime / spray valve. Trigger gun into flushing pail to purge fluid from hose.
12. Open prime / spray valve. Then close. Do not store with prime / spray valve open.
13. Remove filter from gun and sprayer, if installed. Clean and inspect. Reinstall filters.
14. If flushing with water, flush again with mineral spirits or TriTech Pump Cleaner to leave a protective
coa�ng to prevent freezing or corrosion.
15. Unplug power cord from outlet and wipe sprayer, hose and gun with rag soaked in water or mineral
spirits.
PRESSURE RELIEF PROCEDURE
The sprayer’s pressure must be manually relieved to prevent sprayer from starting or spraying accidentally.
Fluid under high pressure can be injected through skin and cause serious injury. To reduce risk of injury from
injection, splashing fluid, or moving parts, Follow the
PressureRelief Procedure
whenever you:
• Are instructed to relieve pressure
• Stop spraying
• Need to check or service any system equipment
• Install or clean spray �p
PROCEDURE
1. Turn pressure control knob counterclockwise to stop.
2. Turn sprayer off.
3
.
Do not unplug power supply cord.
4. Hold metal part of gun firmly to grounded metal container. Trigger gun to relieve pressure.
5. Lock gun safety latch.
6. Open prime / spray valve. Leave prime spray valve open un�l ready to spray again.
NOTE:
If suspected that spray �p or hose is completely clogged, or that pressure has not been fully relieved
after following steps above.
SLOWLY
loosen �p guard or hose end coupling to relieve pressure gradually, and
then loosen completely. Clear �p or hose obstruc�on.