51
602-464
Power
Cord
600-151
Power
Cord
MOTOR
MOTOR
+
+
RED (+) MOTOR
RED (+) MOTOR
MOTOR THERMISTOR
602-358
MOTOR THERMISTOR
602-358
THERMISTOR 602-360
THERMISTOR 602-360
THERMISTOR 602-359
THERMISTOR 602-359
MOTOR LEAD THERMAL
PROTECTION BLACK
602-492 1 OF 2
MOTOR LEAD THERMAL
PROTECTION BLACK
602-492 1 OF 2
MOTOR
THERMAL
PROTECTOR
602-492
2 OF 2
MOTOR
THERMAL
PROTECTOR
602-492
2 OF 2
BLACK
BROWN
RED
BLUE
WHITE
TRANSDUCER 600-036
TRANSDUCER 600-036
INDUCTOR FILTER
602-459
MOTOR SHIELD
GROUND
MOTOR SHIELD
GROUND
POTENTIOMETER
602-407
POTENTIOMETER
602-407
MOTOR LEADS
THERMAL PROTECTION
602-492
MOTOR LEADS
THERMAL PROTECTION
602-492
BLACK (-) MOTOR
BLACK (-) MOTOR
MOTOR
NEG
MOTOR
NEG
MOTOR
POS
MOTOR
POS
602-465
Switch
/ Circuit
Breaker
120V
600-124
Switch
/ Circuit
Breaker
220V
T9 220V WIRING DIAGRAM
T9 110V WIRING DIAGRAM
DIAGRAM
E
DIAGRAM
D
REV. 8/2021
REPLACE CONTROL BOX
Follow the pressure relief procedure before a�emp�ng to service or repair this unit.
If the trouble shoo�ng guide suggests replacing the control box, follow the direc�ons listed below.
1. Remove 6 screws #1 and the Control Box Cover #2 in Diagram C.
2. Disconnect the transducer wire from the circuit board in Diagram D/E. (
GRAY
wire)
3. Unthread the transducer #19 Diagram C from the back of the pump housing #9 in Diagram A using a ¾”
open-end wrench.
4. Disconnect the following wires: The top
BLACK
wire from the on-off switch, the
BLACK
wire from the
thermal protec�on pad, the
RED
&
BLACK
motor leads, the
YELLOW
thermistor wire all on Diagram D/E.
5. Remove the filter housing, #1 on Diagram A for easier access to the three control box moun�ng bolts.
6. Remove the three hex head moun�ng bolts using a 3/8” socket wrench #17 Diagram C.
7. Carefully remove the control box while feeding all of the disconnected wires through the opening in the
back of the box.
8. To install the new control box, follow these steps in reverse order.
NOTE: By removing the motor cover #4 Diagram B, it will make it much easier to install the new control box.
NOTE: If the poten�ometer, transducer & on/off switch are all good, they will have to be removed from the
old box and re-installed into the new box #24 Diagram C.
REPLACE THE POTENTIOMETER
Follow the pressure relief procedure before a�emp�ng to service or repair this unit.
If the trouble shoo�ng guide suggests replacing the poten�ometer, follow the direc�ons listed below.
1. Remove 6 screws #1 and the control box cover #2 both in Diagram C.
2. Disconnect the poten�ometer leads from the circuit board. (Red, Black & Yellow twisted wire) shown in
Diagram D/E.
3. Remove the knob # 16 in Diagram D/E.
4. To reinstall, follow these instruc�on in reverse order.
REPLACE THE TRANSDUCER
Follow the pressure relief procedure before a�emp�on to service or repair the unit.
If troube shoo�ng guide suffests replacing the transducer, follow the direc�ons below.
1. Remove 6 Screws #1 and revove the control box cover #2 in Diagram c.
2. Unplug the transducer wire from the circuit board. (gray wire)
3. Loosen the transducer nut with a ¾” open end wrench and slide the transducer from the filter manifold.
4. Disconnect the
RED
&
BLACK
motor leads, the top
BLACK
wire from the on/off switch, the
BLACK
thermal
protec�on wire and the
YELLOW
thermistor wire. Diagram D/E.
5. Remove 2 screws #20 Diagram C and carefully remove the control box.
6. Remove the transducer by guiding the wire through the circuit board and out through the grome� on the
back of the control box and out through the grommet on the side of the box. Diagram C
7. Install the new transducer by following steps 4 - 6 in reverse order.
8. Thread the transducer into the pump housing making sure the o-ring #21 is in place. Thread the transducer
nut into the pump housing and �ghten with a ¾” open end wrench. Make sure to hold the transducer with a
pair of needle nose pliers to keep it from twis�ng.
9. Rea�ach the control box cover with 6 screws #1. Diagram C