6. Troubleshooting
Power LED not illuminating
Check cable connection between the Mains supply and the connector on the
72V VDSL Adapter.
Check both fuses on the Mains cable and the AC fuse of the unit. See
Section 5.2, “Changing the Fuses” for more information.
Check that the Sonar Power Switch on the unit is set to the correct position.
Ethernet Status and Ethernet Active LEDs not
illuminating
Check that the Ethernet cabling between the computer and 72V VDSL
Adapter is secure and properly fitted at both ends.
Contact
Tritech International Ltd
for more support if you suspect this unit being
faulty.
VDSL Link LED not illuminating
Check that the cabling between the Gemini Sonar and the 72V VDSL Adapter
is secure and properly fitted at both ends.
All LEDs are illuminating, but no communication to
the Gemini Sonar
Check that the IP address of the Gemini and computer are compatible. Please
refer to the relevant Appendix within one of the following manuals: 0685-
SOM-00001, 0695-SOM-00006.