Calibration
9.1
Introduction
If the iGC has been mounted to align closely with the host system’s axes and away from the magnetic
influence of other equipment, it is expected that, in the majority of cases, no further calibration will be
required.
If the full accuracy of the iGC is needed then the system can be calibrated and the necessary offsets
applied.
Note:
For this to be achieved, additional measuring equipment for heading, pitch and roll will be
required. This equipment should have greater accuracy and resolution than the values that are
to be calibrated.
9.2
Physical Offsets
If the iGC has been mounted with reasonable care and with normal manufacturing tolerances, it is
expected that in the majority of cases no further calibration will be required.
If the full accuracy of the iGC is needed then the system can be calibrated and offsets applied either
mechanically or by using the Host system’s control software or the iGC Navigation software (whichever
is being used).
To calibrate the iGC mechanically its mounting bracket should be designed to incorporate vernier
adjustment on the axes to be calibrated.
With the vehicle’s pitch, roll and heading measured or set to known values (e.g. 0º pitch and roll and
known magnetic heading), the mounting bracket is adjusted until the iGC outputs match the measured
reference values.
Where the Host system’s own software is used to process and display the iGC data, fixed offsets to
heading, pitch and roll data can be applied within this software (if this facility is catered for in the
software application).
Where the supplied iGC Navigation software is used, heading, pitch and roll offsets can be easily
applied from the system set-up screen. These offsets are added in the PC software only, and will
adjust the live data as it is displayed. They do not adjust the actual output data from the iGC.
9.3
Magnetic Offsets
Magnetically generated offsets that remain after mounting the iGC as far away from magnetic
influences as possible can in certain cases be calibrated out by conducting a compass swing
calibration procedure.