15
Electric shower
FITTING THE COVER
Fit the trimplate.
Turn the valve spindle fully clockwise until it stops
(fig.13).
Turn the temperature flow control on the cover
fully clockwise to the minimum flow position
(fig.14)
.
Fitting of the cover assembly will be simplified if
the cover retaining screws are fitted into the
backplate before starting the installation
(fig.15)
.
Offer the cover to the unit.
Carefully locate the cover tags into the guide
pockets on the backplate, ensuring the wires and
ribbon cable are not trapped.
Guide the cover into position so that the control
spindle locates correctly - minor adjustment may
be necessary to align the control and spindle.
While applying slight pressure to the cover,
secure in position with the retaining screws.
Fit the hose to the shower outlet making sure
the outlet of the hose is directed to waste. Check
the supplied sealing washer is in place.
DO NOT attach the shower head at this
stage.
IMPORTANT
DO NOT
connect the 10-way
ribbon cable before the commissioning
procedure has been completed.
>POM-GF30<
>POM-GF30<
Valve
spindle
Fig.13
Fig.14
Temperature flow
control at minimum
flow position
WARNING
COVER RETAINING SCREWS
ONLY
the
SUPPLIED SCREWS
should be
used. The use of non supplied screws
WILL
invalidate product specifications & warranty.
Fig.15
Top left
Top right
Bottom middle
Summary of Contents for 10.5kW
Page 25: ...25 Electric shower ...
Page 26: ...26 Electric shower ...