CLEANING THE FILTERS
NOTE: Switch off the electricity supply and
turn off both hot and cold water supplies to
the unit before proceeding further.
Remove the shower unit cover by first pulling off
the temperature control and then remove the two
fixing screws – top and bottom. NOTE: Be aware
of the lead connected to the PCB unit. Carefully
pull off the lead from the PCB. DO NOT let the
cover dangle by the lead.
Remove the single retaining screw from either the
upper or lower filter cover
(fig.54)
, depending
upon whether top/rear entry or bottom entry is
used.
Pull off the filter cover.
Carefully hook out the filters together with ‘O’
rings. Thoroughly clean and replace ensuring the
‘O’ rings are in position.
Refit the filter cover and secure with the screw.
Offer the cover to the unit and replace the four
wire lead to the PCB. Secure the cover with the
top and bottom fixing screws. Replace the
temperature control.
Summary of Contents for Aquasensation AS2000
Page 28: ...UKAS QUALITY MANAGEMENT 003 ...