27
Phased Shutdown
In use, every time the Start/Stop button is pressed, power
is switched off to the elements. Water will continue to flow
for a few seconds, purging any remaining hot water. This
makes sure the next immediate user will not receive a
slug of hot water if standing under the showerhead when
starting the shower.
Important: DO NOT switch off the shower unit using
the isolating switch before the phased shutdown
process has completed. This may damage the unit.
Temperature Protection
During normal operation if the flow of water through the
unit is restricted, power to the elements will be reduced to
maintain the shower temperature. When the flow of water
through the unit returns to normal, power to the elements
will be automatically restored to the setting at the time of
interruption.
Safety Cut-out
The unit is fitted with an over-temperature safety device.
In the event of abnormal operation which could cause
unsafe temperatures within the unit, the device will
disconnect the heating elements and remove power from
the electronics making the shower unit inoperable.
It will require a visit from a qualified engineer to
identify the nature of the fault and replace the safety
device.
IMPORTANT
The shower unit
MUST BE
switched off at the
isolating switch when not in use. This is a safety
procedure recommended for all electrical appliances.