background image

8

Starting your shower

To start the Triton Digital Shower, press the start/stop button (      ) or your 

desired preset button (    ) / (         ), the shower will then commence. The 

target temperature will flash until it is reached.

Activate

Deactivate

To stop the shower

Press the start stop button       on the control panel and your shower will 

stop, after 1 second the display screen will go blank and the shower will 

enter into sleep mode. Alternatively deselect the outlets       &          to stop 

the shower, after 5 seconds the display screen will go blank and the shower 

will enter into sleep mode.

Note: If the shower has been in sleep mode for 3 minutes, it will 

restart using default settings, if enabled (see page 13).  

Switching

On and Off

Summary of Contents for Digital Mixer Shower

Page 1: ...2181517C April 2018 User Guide DIGITAL MIXER SH WER tritonshowers co uk digital European Union Registered Design No 004558245 0001 10 ...

Page 2: ...2 ...

Page 3: ...presets Settings and configuration Max Shower Temp Setting Max Shower Time Setting Default Shower Temp Setting Default Shower Flow Setting Default Outlet Setting Outlet Icons Screen Colour Commissioning Factory Reset Product Care Cleaning Replacing the batteries Wireless connectivity Individual accessories 4 5 6 7 8 9 10 11 12 13 14 14 14 15 15 15 16 16 16 17 17 18 19 Contents ...

Page 4: ...ry The Digital Mixer Processor unit MUST only be used with the AC power supply cable provided If this supply cable is damaged it must be replaced by a Triton engineer or similar qualified persons to avoid a hazard This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience or knowledge if they have been g...

Page 5: ...crease Flow decrease Temperature increase Preset 1 Sleep mode Preset 2 Sleep mode Outlet 1 Active mode Outlet 2 Active mode Temperature decrease Active mode outlet sections are only available on multi outlet product versions Digital shower controller ...

Page 6: ...wering Only available with the start stop accessory Flow Rate Full Cold Accept Relax Preset Energise Preset READY Showering water warming up to the target temperature Only available with the start stop accessory WARMING UP Display screen icons Return Preset icons Operating icons Outlet type icons Warning icons Configure icons Display messages ...

Page 7: ... and increase buttons Adjust the temperature with the temperature dial Select between your two outlets using the outlet buttons or press both to run them at the same time 1 To power down the shower press the start button or alternatively deselect the outlets using buttons 2 3 4 5 Quick start outlet selections are only available on multi outlet product versions ...

Page 8: ...s the start stop button on the control panel and your shower will stop after 1 second the display screen will go blank and the shower will enter into sleep mode Alternatively deselect the outlets to stop the shower after 5 seconds the display screen will go blank and the shower will enter into sleep mode Note If the shower has been in sleep mode for 3 minutes it will restart using default settings...

Page 9: ...kwise to increase the temperature and anti clockwise to decrease the temperature When the temperature is adjusted the temperature display will flash until the target temperature is reached Small changes to the temperature may change quickly and prevent the temperature read out from flashing Adjusting the temperature ºC 35 ...

Page 10: ... its lowest setting and 10 being it s maximum Increasing the flow rate To increase the flow rate of the shower press button Decreasing the flow rate To decrease the flow rate of the shower press button 10 1 Adjusting the flow The amount of the green outer circle will change as the flow is adjusted ...

Page 11: ...ed by pressing the outlet 1 or outlet 2 buttons Single outlet product versions will display only one icon on the display screen and buttons and will only operate the presets as described in selecting presets on page 12 Single Outlet Control Dual Outlet Control Outlet Icons By default your Digital Controller will show the following icons these can be configured to your outlet types see page 15 Outl...

Page 12: ...wn personal preset Presets can only be activated from sleep mode Creating personal presets When you create personal user presets they will automatically overwrite the factory programmed presets A maximum of 2 presets can be saved to memory Adjust your Digital Shower to the desired flow temperature settings and select your preferred outlets whilst the shower is running press and hold down the prese...

Page 13: ...gure and personalise You can enter the configure menu whether you are showering or the Digital Controller is in sleep mode To activate the configure menu press and hold the Start Stop button and the Flow decrease button for 3 seconds Outlet Icons Configure Settings and configuration Max Shower Temp Max Shower Time Default Shower Temp Default Shower Flow Outlet Icons Screen Colour Commissioning NOT...

Page 14: ... automatically shut down Using the temperature dial select your maximum time Save the setting using the accept button Default factory setting is 30 min Settings and configuration ºC 38 Default ShowerTemp This specifies the default temperature for shower outlets Default Shower Temp setting This will set the showering temperature from any of your shower outlets when default showering is activated Th...

Page 15: ...let setting This will set which outlet is used when default showering is activated The default outlet can be set to either outlet 1 or outlet 2 Using the temperature dial select your outlet Save the setting using the accept button Default factory setting is 1 Only available on multi outlet product versions Outlet Icons This setting enables you to choose the outlet icon that represents your outlet ...

Page 16: ...ur BLUE Factory reset The factory reset will return all configuration options presets and shower settings back to default factory settings To confirm the change you must press and hold the Yes button for 5 seconds The No button will cancel the action Commissioning This setting returns your Digital Mixer Shower into commissioning mode Refer to the Installation guide for further information Restore ...

Page 17: ...m soapy water using a micro fibre cleaning cloth eg E cloth or sponge ONLY DO NOT use a general purpose cleaning cloth eg J cloth dish cloth or scourer DO NOT use abrasive or aggressive chemical cleaning products as this may affect the product surface finish and invalidate your guarantee Replacing the batteries ...

Page 18: ...d to have its wireless connection reset To reset the Digital Control Panel wireless connection follow the procedure below Isolate the electricity supply to the Digital Mixer Processor Unit After at least 1 minute restore the electricity to the Digital Mixer Processor Unit Within 2 minutes press and hold the flow control buttons together and hold them down for at least 5 seconds Wireless connectivi...

Page 19: ...the shower and bring up to temperature while you get a bit longer in bed The warm up is completed in seconds and automatically stops should you return to the land of nod Locate on a bedside table or on the supplied magnetic wall mount To buy this accessory please visit the Triton Website or see Triton Showers Stockist for a local store www tritonshowers co uk find a store ...

Page 20: ...ire tritonshowers co uk Website tritonshowers co uk Brochure enquiries 44 0 24 7632 4460 Triton Showers is a division of Norcros Group Holdings Limited Triton Showers Triton Road Nuneaton Warwickshire CV11 4NR It is our policy to improve the design and specification of our products and we reserve the right to depart from the design given without prior notice firstthing ...