Purificare ©2015
8
Electronic Controls & Startup Procedures
10. Dealer Information - This screen contains dealer
contact information. If you touch the right green arrow
you will see a scanable QR code which can be scanned
with a smart phone to obtain dealer information. (as
shown in fig 5 & 5A)
11. Software Version - This screen displays the current
software version for the cercuit board. (as shown in fig 6)
OPERATING INSTRUCTIONS
Your UV System is equipped with the ATS-287-2 UV
Lamp Detector and Timer circuit board which is designed
to provide a continuous monitoring system of the UV lamp
operational status. This is also equipped with an internal
and external fused surge protection system. This solid state
electronic circuit board provides the latest in Touchscreen/
UV lamp monitoring technology.
UV LAMP / CONTROL BOX START UP
PROCEDURE
1. Make sure the UV lamp is inserted per instructions into
the quartz sleeve and UV chamber. Then plug the UV
lamp into the lamp connector.
2. Plug the electrical control box into a 120volt wall plug
outlet.
3. Upon start up the UV lamp Detector and Timer circuit
board will perform a self diagnostic test. When power
is applied the circuit board will perform an output check
to see if lamp or probe is connected. Once detected,
the lamp will light and go into an approximate 2 minute
lamp optimization period. (as shown in fig 1 - 1D)
4. Quick Beep
5. The number 364 is displayed representing 364 days
remaining
6. Once warmed up, the logo and number of remaining
days is displayed.
7. Set the 1 Year Lamp Timer – WITH NEW UV LAMP\
Make sure the control box is plugged into the wall
outlet and the UV lamp is on. Touch the right green
arrow until “Reset lamp” is displayed. Touch the red
“reset” button and then touch the green check mark to
rest lamp for 1 year. (as shown in fig 2 & 2A)
8. Snooze Alarms
• Touch to snooze alarm or touch the
button on display or control box.
9. Alarm screens
A. Lamp Out (as shown in fig 3 & 3A)
• Circuit board has detected lamp out. Unplug
unit and check lamp connection, and plug the unit back
in.
B. Lamp Life Low (as shown in fig 4)
• Circuit board has detected that there are 30 days
remaining on the lamp life.
overlay
UV%:
DAYS:
100%
364
ENHANCED DISINFECTION