INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY
Instructions for installers and service engineers only
CLEANING THE FILTER
CLEANING THE FILTER
It is recommended that the filter is periodically
cleaned in order to maintain the performance of
the shower. It is essential that this operation is
carried out by a competent person.
IMPORTANT:
Before servicing, switch off the
electricity supply at the mains.
• Switch off the water supply at the lsolator
valve.
• The inlet filter is situated inside the filter
assembly
(fig.21)
.
• To gain access to the filter, remove the cover.
• Unscrew the filter cap from the inlet.
• Inspect the ‘O’ ring for damage when the
filter cap is removed.
• When cleaning the filter,
DO NOT
use a
sharp object as it will cause damage. It is
preferable to use an old toothbrush or similar.
• To reassemble, follow the procedure in
reverse.
• Make sure that the sealing ‘O’ ring is in
place.
•
DO NOT
over tighten the filter cap on
reassembly.
IMPORTANT:
Before replacing the cover, it is
strongly advised to prime the unit by opening
the bleed screw until water drains from it.
•
Close the bleed screw and replace the cover.
Secure it with the fixing screws.
•
Switch on the electric supply and start the
shower on the cold setting only and with the
temperature control rotated fully
anti-clockwise.
•
When a smooth flow of water is obtained,
the shower can then be used in the normal
manner.
Fig.21
Filter
‘O’ ring
Filter cap