background image

Triton Systems ©

2

TDN 07103-00241     Rev: B

 

Revision

ECO

Date

Description

A

Original

5/1/2015

Upgrade to T9 Keypad

B

6/22/2022

Upgrade to T10 Keypad, change images and text

Contact Information 

Triton© 

 

 

 

 

 

21405 B Street  

 

 

 

 

 

Long Beach, MS 39560 USA   

 

 

 

1 (866) 787-4866 (opt 3) or +1 (228) 575-3100 (opt 3) 

 

 

 

 

 

(228) 575-3101 (fax)   

 

 

 

 

CSS@triton.com
techsupport@triton.com

 

 

 

 

 

 

 

 

 



  is guide covers keypad upgrade and activation information for Triton Traverse.



  is manual applies to all service personnel involved in installing, con  guring, or upgrading so ware/hardware 

on Triton ATMs nationwide and abroad. 



  is guide provides easy-to-follow instructions for upgrading the EPP keypad to a T10 Keypad. 

**WARNING**

Once the T10 EPP Keypad is installed and activated in the unit, it CANNOT be removed.   
 
If the keypad is removed from the unit a er activation, reactivation is required and can only be performed by 
following the steps 3-9 starting on page 7.

  e T10 EPP Keypad is mostly identical to the T5 EPP Keypad except for:

•  

  e T10 EPP contains  removal detection switches that deactivates / TAMPERS the EPP if the EPP is ever 

removed from the ATM. 

•  Le  and right halves of 3DES keys must be diff erent. 
•  No two 3DES keys may have the same value. 
•  When replacing current keypad with a T10 EPP, activation is required upon installation. 

**NOTE**

Traverse built on or a er June 18, 2014 (Julian date: 14169) for SDD and July 8, 2014 (Julian date: 14189) for 
SCDU and HCDU do not require a kit.

Summary of Contents for Traverse T10 EPP

Page 1: ...Triton Systems of Delaware LLC e third party trademarks that may be identi ed herein are the trademark of their respective owners Triton disclaims any a liation connection or association between its p...

Page 2: ...s for upgrading the EPP keypad to a T10 Keypad WARNING Once the T10 EPP Keypad is installed and activated in the unit it CANNOT be removed If the keypad is removed from the unit a er activation reacti...

Page 3: ...Triton Systems 3 TDN 07103 00241 Rev B Table of Contents...

Page 4: ...anel Flip the switch on the power supply to the OFF 0 position If possible unplug the ATM power cord at the wall outlet Tools Required 2 Phillips screwdriver KITS 06200 05210 Canada T10 PCI 5 Upgrade...

Page 5: ...Control panel with provided alcohol wipes 4 Peel adhesive from backing 5 Position bracket 1 inch from top as shown in next image Use credit card to align bracket edge with opening 6 Apply enough press...

Page 6: ...bled your screens appears as Right Image Function numbers are the same for either screen 3 e Remove Detector Activated will read TRUE for a correctly installed T10 EPP keypad and FALSE if the keypad i...

Page 7: ...e will require the following information Operator ID EPP Serial Number Nonce Number and the ATM serial number Get the ATM serial number from inside the Control Panel 4 Log into www triton com Navigate...

Page 8: ...PP Activation dialog then press the Enter and Return button 8 When activation is complete the EPP activation successful message screen appears Press the Enter button and return to Keypad Diagnostics m...