2HJ/2HK
2-3-2
Connector
Pin No.
Signal
I/O
Voltage
Description
CN1
1
AC (LIVE)
I
220 -240 V AC
120 V AC
AC power input
Connected
to the AC
inlet
2
-
-
-
Frame ground
3
AC (NEUTRAL)
I
220 -240 V AC
120 V AC
AC power input
YC901
1
TH1
O
Analog
Fuser thermistor 1 detection voltage output
Connected
to the
engine con-
troller PWB
2
TH2*
1
O
Analog
Fuser thermistor 2*
1
detection voltage output
3
FDSOLDR
I
0/24 V DC
Face up/down solenoid control signal
4
+5V2
O
5 V DC
5 V DC power output
5
RCOVOPN
O
0/5 V DC
Rear cover open/close sensor: Rear cover Open/Close
6
FUSOLDR
I
0/24 V DC
Face up/down solenoid control signal
7
EXITPAPN
O
0/5 V DC
Exit sensor: On/Off
8
+24V2
O
24 V DC
24 V DC power output
9
HEAT2DR*
1
I
0/24 V DC
Fuser heater lamp 2*
1
: On/Off
10
HEAT1DR
I
0/24 V DC
Fuser heater lamp 1: On/Off
11
ZCROSS
O
0/5 V DC (pulse)
Zero cross signal output
12
-
-
-
N.C.
13
+24V1
O
24 V DC
24 V DC power output
14
+24V1
O
24 V DC
24 V DC power output
15
+24V1
O
24 V DC
24 V DC power output
16
+24V1
O
24 V DC
24 V DC power output
17
GND
-
-
Ground
18
GND
-
-
Ground
19
GND
-
-
Ground
20
GND
-
-
Ground
21
GND
-
-
Ground
22
GND
-
-
Ground
23
GND
-
-
Ground
24
GND
-
-
Ground
25
+3.3V1
O
3.3 V DC
3.3 V DC power output
26
+3.3V1
O
3.3 V DC
3.3 V DC power output
27
+3.3V1
O
3.3 V DC
3.3 V DC power output
28
+3.3V1
O
3.3 V DC
3.3 V DC power output
29
+5V1
O
5 V DC
5 V DC power output
30
+5V1
O
5 V DC
5 V DC power output
YC902
1
GND
-
-
Ground
Connected
to the fuser
PWB
2
+24V2
O
24 V DC
24 V DC power output
3
FDDR
O
0/24 V DC
Face up/down solenoid control signal
4
EXITPAPN
I
0/5 V DC
Exit sensor: On/Off
5
FUSOLDR
O
0/24 V DC
Face up/down solenoid control signal
6
+5V1
O
5 V DC
5 V DC power output
7
RCOVOPN
I
0/5 V DC
Rear cover open/close sensor: rear cover Open/Close
8
TH1
I
Analog
Fuser thermistor 1 detection voltage output
9
TH2*
1
I
Analog
Fuser thermistor 2*
1
detection voltage output
YC903
1
HEATER LIVE*
1
O
220 -240 V AC
120 V AC
AC power output for fuser heater lamp 2*
1
Connected
to the fuser
heater lamp
1 and 2*
1
,
fuser ther-
mostat 1
and 2*
1
2
NC
-
-
Not Connected
3
HEATER COM
O
220 -240 V AC
120 V AC
Fuser heater lamps output (common)
4
NC
-
-
Not Connected
5
HEATER LIVE
O
220 -240 V AC
120 V AC
AC power output for fuser heater lamp 1
*
1
: 16 ppm printer only.
Summary of Contents for CLP3316
Page 1: ...Service Manual Color Printer CLP 3316 CLP 3520 X First Edition Date 24 10 2006 2HKSM060 ...
Page 2: ...Service Manual Color Printer CLP 4316 CLP 4520 X First Edition Date 24 10 2006 2HKSM060 ...
Page 6: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 20: ...2HJ 2HK 1 1 8 This page is intentionally left blank ...
Page 32: ...2HJ 2HK 1 2 12 This page is intentionally left blank ...
Page 138: ...2HJ 2HK 1 6 4 This page is intentionally left blank ...
Page 168: ...2HJ 2HK 2 1 30 This page is intentionally left blank ...
Page 172: ...2HJ 2HK 2 2 4 This page is intentionally left blank ...
Page 188: ...2HJ 2HK 2 4 6 This page is intentionally left blank ...