3NG
2-3-2
Connector
Pin
Signal
I/O
Voltage
Description
YC5
1
GND
-
-
Ground
Connected to
the SD con-
nection
switch, SD
paper feed
solenoid, SD
paper sensor,
SD upper limit
sensor, SD
feed sensor.
2
MC_SW
I
0/3.3 V DC
SDCS: On/Off
3
N.C
-
-
Not used
4
24V1
5
N.C
-
-
Not used
6
GND
-
-
Ground
7
RESERVE
8
24[V]
O
24 V DC
24 V DC power output to SDPFSOL
9
FD_SOL_ACT
O
0/24 V DC
SDPFSOL: On/Off (actuate)
10
FD_SOL_KEP
O
0/24 V DC
SDPFSOL: On/Off (keep)
11
EPSW_PW
O
1.2 V DC
1.2 V DC power output to SDPS
12
GND
-
-
Ground
13
EPSW
I
0/3.3 V DC
SDPS: On/Off
14
U_LIMT_SW_P
W
O
1.2 V DC
1.2 V DC power output to SDLS
15
GND
-
-
Ground
16
U_LIMT_SW
I
0/3.3 V DC
SDLS: On/Off
17
3.3V1
O
3.3 V DC
3.3 V DC power output to SDFS
18
LD_PS
I
0/3.3 V DC
SDFS: On/Off
19
GND
-
-
Ground
YC6
1
RDEP_SW1_PW
O
1.2 V DC
1.2 V DC power output to SDPGS1
Connected to
the SD paper
gauge sensor
1, SD paper
gauge sensor
2, SD lower
limit sensor,
SD deck
detection
switch.
2
GND
-
-
Ground
3
RDEP_SW1
I
0/3.3 V DC
SDPGS1: On/Off
4
RDEP_SW2_PW
O
1.2 V DC
1.2 V DC power output to SDPGS2
5
GND
-
-
Ground
6
RDEP_SW2
I
0/3.3 V DC
SDPGS2: On/Off
7
N.C
-
-
Not used
8
GND
-
-
Ground
9
N.C
-
-
Not used
10
N.C
-
-
Not used
11
GND
-
-
Ground
12
N.C
-
-
Not used
13
L_LIMT_SW_P
W
O
1.2 V DC
1.2 V DC power output to SDLLS
14
GND
-
-
Ground
15
L_LIMT_SW
I
0/3.3 V DC
SDLLS: On/Off
16
N.C
-
-
Not used
17
GND
-
-
Ground
Summary of Contents for Utax PF 770
Page 1: ...Service Manual 3DSHU HHGHU 3 5HY Date 0 20 1 60 ...
Page 2: ...Service Manual 3DSHU HHGHU 3 5HY Date 0 20 1 60 ...
Page 4: ...Revision history Revision Date Replaced pages Remarks 1 6 April 2011 CONTENTS 2 4 1 to 2 4 3 ...
Page 5: ...This page is intentionally left blank ...
Page 11: ...This page is intentionally left blank ...
Page 16: ...3NG 1 1 3 1 1 3 Machine cross section Figure 1 1 2 Paper path ...
Page 17: ...3NG 1 1 4 This page is intentionally left blank ...
Page 69: ...3NG 1 5 12 This page is intentionally left blank ...
Page 77: ...3NG 2 3 4 This page is intentionally left blank ...