TX6351 • TX6352 User Manual
4 P5536.1600 rev B
P5536.1600 rev B 5
1. Product Overview
TX6351
3/4 wire device with separate output signal and power lines.
Can be used with any Sentro eModule
TX6352
2-wire line powered 4 to 20 mA output signal.
Can ONLY be used with electrochemical Sentro eModules
1.1 Operating Features
• Fixed sensor for detection of Toxic Gases and Flammable Gases
• Exclusive pre-calibrated plug-in gas sensing modules for many types of gas and
climatic conditions
• LCD readout and visual LED alarm indicators
• Choice of supply voltage and output signal format
• Heavy duty housing to IP65, EMC compliant
• STEL and TWA monitoring for selected gases
1.2 Application
Fixed point gas detection for safety monitoring in hazardous areas and general purpose
applications.
Underground Mining and Tunnelling
Ex ia I Ma
TX6351.01i
TX6352.01i
Supply Voltage: 12 V dc from an
approved power source
Type of protection:
Intrinsically safe. Ex ia
Category: I M1
General Purpose
TX6351.03
TX6352.03
Supply Voltage: 24 V dc
1.3 Product Options
4-wire connection
Mining Ex ia
General Purpose
0.4 to 2 V output
TX6351.01i.11
-
4 to 20 mA output
TX6351.01i.12
TX6351.03.12
5 to 15 Hz output
TX6351.01i.13
-
Contact output
TX6351.01i.14
TX6351.03.14
RS485 output
TX6351.01i.15
TX6351.03.15
*2-wire line powered
Mining Ex ia
General Purpose
4 to 20 mA output
TX6352.01i.12
TX6352.03.12
*For use with Toxic Gas Sentro eModules only