TX6351 • TX6352 User Manual
P5536.1600 rev A 13
Toxic gases • Electrochemical cells
Selected toxic gas modules are equipped with automatic
STEL/TWA calculation in accordance with EH40.
TX6350
.250.50
.250.250
.250.300
.250.500
.251
.252
Carbon
Monoxide
CO
Carbon
Monoxide
CO
Carbon
Monoxide
CO
Carbon
Monoxide
CO
Hydrogen
Sulphide
H
2
S
Sulphur
Dioxide
SO
2
Sensing
element
Electrochemical cell
Sensing
range
0 to
50 ppm
0 to
250 ppm
0 to
300 ppm
0 to
500 ppm
0 to
50 ppm
0 to
20 ppm
Linearity
±2% FS
Drift
2% per month
Repeatability
±2%
Response
time T63%
<20 secs
<30 secs
<20 secs
Operating life
2 years
Relative
humidity
15 to 90% non-condensing
Operating
temperature
-10 to +40°C
GENERAL
alarm
15 ppm
25 ppm
25 ppm
25 ppm
5 ppm
5 ppm
HIGH alarm
30 ppm
100 ppm
100 ppm
200 ppm
10 ppm
10 ppm
STEL & TWA
200 ppm
200 ppm
200 ppm
200 ppm
10 ppm
5 ppm
30 ppm
30 ppm
30 ppm
30 ppm
5 ppm
2 ppm