20 P5536.1600 rev A
2.5 Australia (IECEx)
Ex certified for use in Ma applications:
Australia (IECEx):
TX6351.01i.xx/TX6352.01i.xx
Ex Certificate number: IECEx ITA 14.0006X
Ex Certification code: Ex ia I Ma
Conditions of Safe Use
The following safety parameters are applicable to the Sentro 1 Sensor/Transmitters:
Model
Terminals
Input Parameters
Ui
li
Ci
Li
Pi
TX6351.01i.11
and
TX9081.01i.11
5 WRT 6
14.4 V
* 1
* 2
* 3
-
1 WRT (2 or 3)
-
-
-
-
-
TX6351.01i.12
and
TX9081.01i.12
5 WRT 6
14.4 V
* 1
* 2
* 3
-
1 WRT (2 or 3)
-
-
-
-
-
TX6351.01i.15
and
TX9081.01i.15
5 WRT 6
14.4 V
* 1
* 2
* 3
-
1 WRT 2
2 WRT 3
-
-
-
-
-
TX6351.01i.14
and
TX9081.01i.14
5 WRT 6
14.4 V
* 1
* 2
* 3
-
1 WRT 2
30 V
* 1
0
0
-
3 WRT 4
30 V
* 1
0
0
-
TX6351.01i.13
and
TC9081.01i.13
5 WRT 6
14.4 V
* 1
* 2
* 3
-
1 WRT 2
16.5 V
-
0
0
2.5 W
TX6352.01i.12
1 WRT 2
14.4 V
* 1
* 2
* 3
-