8

 

   

:  Moves the cursor over next item. 

 E 

  

:  Enters the menu displayed or confirms the changes. 

Esc

  

:  Returns to previous menu or to the General Viewing state. 

 
Also, if you don’t press any button for 15 seconds while navigating through menus to configure 

the device, it automatically returns to the General Viewing state. 

 

 

9. Device Setup 

 
Quattron  VSB  must  be  configured  in  order  to  output  desired  channels  to  your  distribution 

system or television. Following steps guide the setup of the device. 

 

9.1  Module Setup 

 
To  configure  the  output  channels,  output  signal  levels  and  test  signals  of  the  independent 

modulator units inside the Quattron VSB device, hold 

  E 

  button for 1 second while in the General 

Viewing state. “

Programming SET MODULE 1

” text will be displayed on the LCD display and the 

blinking cursor will be over “

1

” digit. This digit shows the module number which will be configured. 

Use 

  to choose the module you wish to configure. When the number of the module you wish is 

displayed, press 

  E 

  button. Some menus to make following 3 configurations will be displayed: 

 

1. Set Output Channel:

 

Sets  the  output  channel  of  the  modulator  unit.  Output  channel 
expression consists of 1-2 letters and 2 digits. The cursor is  over 
the letters in beginning. To navigate through letters and digits, use 

  and 

  buttons.  To  alter  the  item  the  cursor  is  over,  use 

 

button.  Use 

  E 

  button  to  confirm  and  to  proceed  to  next  step 

when you have finished this setting. 

2. RF Output Level:

 

Sets  the  independent  output  level  of  the  modulator  unit.  In  this 
step, use 

  and 

  buttons to increase or decrease the number 

of  black  squares.  More  black  squares  means  the  higher  output 
level.  There  is  7  dB  difference  between  maximum  and  minimum 
levels.  Use 

  E 

  button  to  confirm  and  to  proceed  to  next  step 

when you have finished this setting. 

3. Test Signal:

 

Switches  the  module  to  show  two  vertical  bars  on  the  screen  as 
the test signal instead of audio and video received from AV inputs. 
There  are  2  options: 

NO

  and 

YES

.  Alter  your  selection  with 

 

button and press 

  E 

  button to confirm. Since this step is the last 

configuration in this sequence, the device will automatically return 
to the beginning of module setup menu. 

 
By  changing  the  module  number,  you  can  set  up  all  of  modules  via  above  steps.  When  you 

alter  some  settting  of  a  module,  changes  are  automatically  applied  to  RF  output.  After  you 
complete the setup of all modules, the device will automatically return to General Viewing state. 

 

9.2  Quick Setup 

 
The  step  by  step  setup  of  modules  performed  in  previous  method  can  be  performed  via  this 

method on a single screen and more quickly. To access the quick setup menu, hold both 

  and 

  buttons for 2 seconds while the device is on General Viewing state. Some expression similar to 

below will appear on the LCD display: 

 
 

Summary of Contents for Quattron VSB Full 1-2

Page 1: ...USER MANUAL v1 0 3 September 2009 QUATTRON VSB FU LL B A ND SMATV MODULATORS 4 8 CHANNELS 19 2U SINGLE SIDE BAND 1 2 CHANNELS 19 1U SINGLE SIDE BAND www tron com tr...

Page 2: ......

Page 3: ...view 5 2 Features 5 3 Safety Warnings 5 4 Unpacking 5 5 Front Panel 6 6 Rear Panel 6 7 Installation Steps 7 8 General Viewing and Basic Operations 7 9 Device Setup 8 9 1 Module Setup 8 9 2 Quick Setup...

Page 4: ...ditions 1 Damage on power cord or plug 2 Equipment gets wet or substantial moisture enters the chassis 3 Equipment exposed to rain or water 4 Equipment is dropped or damaged 5 You detect some irregula...

Page 5: ...and external structure within 19 2U and 19 1U rack type housings F type RF RCA type AV connectors 3 Safety Warnings 1 Quattron VSB shall be operated in ventilated environment and away from heat sourc...

Page 6: ...nal generated by this device are combined A5 RF Output RF signal output to be connected to distribution system or to next device in queue 6 Rear Panel A1 A2 Esc E QUATTRON VSB QUATTRON VSB QUATTRON VS...

Page 7: ...d to the AC Power Input at the rear of Quattron VSB then power on the device via power switch on rear panel There is 3 seconds delay during boot up 6 After setting the device with correct TV channel p...

Page 8: ...digits use and buttons To alter the item the cursor is over use button Use E button to confirm and to proceed to next step when you have finished this setting 2 RF Output Level Sets the independent o...

Page 9: ...will automatically return to that state after 15 seconds of inactivity 9 3 System Setup This section is intended only to guide advanced system installers to adjust channel standards While Quattron VSB...

Page 10: ...nal RF Input Impedance 75 Combined RF Output Level 92 dB V 90 dB V Combined RF Output Lvl Adj 20 0 dB RF Input Output Combined RF Output Imp 75 Audio Input Level 500 mV 6 dB RMS Audio Input Impedance...

Page 11: ...QUATTRON VSB SMATV Modulator 11...

Page 12: ...R SAN VE TIC A S General Distributor TRODIO ELEKTRONIK PAZARLAMA LTD STI Adress 1 Esensehir Mah Mimar Sinan Cad No 33 34776 Yukari Dudullu Umraniye Istanbul TURKEY Tel 90 216 313 33 35 Fax 90 216 313...

Reviews: