- 6 -
• Should the adapter plugs
be connected with
opposite markings (+ and -) on the adapter cable
, then on the adapter plugs
positive is outside
and negative is inside.
Providing electrical power
1. Place the main switch
2
to "ON" – the appliance
connected via the adapter cable
is supplied
with electricity.
2. For as long as sufficient energy is available for
the appliance being supplied, the green LED
“Full”
5
is illuminated in the OUTPUT field.
3. When there no longer sufficient energy available
for the appliance being supplied, the red LED
"Empty"
5
is illuminated in the OUTPUT field.
Caution!
You must first recharge the battery when the red LED
“Empty”
5
is illuminated. Otherwise the battery will
be depleted, usually resulting in a considerable loss
of charging capacity.
Ending the supply of electricity
1. Switch the appliance off that is being supplied
with power.
2. Place the main switch
2
of the Energy Station at
"OFF" (centre position).
In this way you prevent current flowing while the
connector is being withdrawn. Sensitive appliances
sometimes malfunction as a consequence.
3. Now you can withdraw the adapter cable plugs
from both the appliance and the Energy
Station.
Possible faults in the event of
non-functionality
• If neither of the two LEDs,
5
and
6
, light up
after switching on, then the 10 amp fuse
8
on
the Energy Station might have blown. Changing
fuses is described in more detail in the section
"Fuses".
• Should an LED light up on the Energy Station
after switching on, but the appliance fails to work,
immediately switch the Energy Station off. Check
to ensure that the cable is correctly connected –
and “Positive” and “Negative“ have not been swit-
ched. If required, also check the fuse in your
appliance, as described in its operating
instructions.
Power supply over the 10 amp
socket (Vehicle power plug)
Caution!
Before performing any connections, always check
to ensure that both the appliance to be supplied
and the Energy Station are switched off. Place the
main switch
2
in the “OFF” position (centre position).
In this way you can avoid damage through connec-
tion faults.
The 12 V/10 A socket
3
is available for the supply
of electricity to appliances consuming up to a max.
of 10 A. Here you can connect the so-called “ciga-
rette lighter connectors” for various appliances.
These could be for example...
-
cooler boxes,
-
car vacuum cleaners,
-
small portable TV sets etc. ...