background image

Non

-

woven contamination settings.

 

 

The first 

is to adjust the height of the sensor in the 

cassette, if you lower it, the non

-

woven fabric should 

scroll more often (the dirty non

-

woven fabric will be 

lighter).

 

 

The second 

setting is the lower window on the left 

side of the cassette, after opening some of the 

water does not pass through the fleece. This 

solution is important because after our tests we 

noticed that after some time of using the roller, the 

water becomes too poor, so in this case, you should 

not pass 100% of the water through the filter fleece.

 

 

Attention!!! 

The roller with the motor is not 

waterproof, therefore when replacing the dirty 

fleece, unplug the motor plug and move the motor 

with the dirty fleece to a safe place and remove it 

there.

 

 

Use and maintenance.

 

 

After each used roll:

 

 

-

 check that the drain strainer in the cassette is 

inside and outside free of contamination (e.g. algae, 

solid elements such as snail shells / snails, sand, 

etc.),

 

-

 check that the rollers are clean,

 

-

 check if the float sensor is working lightly and the 

axis on which it moves (in case of problems, remove 

the pin, remove the float and wash it thoroughly in 

RO water),

 

-

 check for signs of corrosion / tarnish on the sensor,

 

-

 check for moisture from the plugs connecting the 

motor and sensor with the controller,

 

-

 check if the fleece is rewound in accordance with 

the diagram on the upper cassette,

 

-

 after installing the roller with the motor, pay special 

attention to whether it fits well on the handles.

 

 

ATTENTION 

-

 the use of non

-

original reels, 

driver, power supply, sensor is associated with 

the loss of warranty! The maximum water flow is 

8000L / h.

 

 

 

Solving problems

 

 

 

  

Problem 

  

Cause / Solution

 

  

 

 

 

Motor fault (red LED)

 

 Motor fault protection has tripped. 

This is due to solid elements that have passed 

through the strainer and blocked between the 

fleece and the lower rear roller. 

Solution - remove the cassette, open the drain 

valve to 100% and clean the drain pipes / chim-

ney of small solids (snails, hard algae, etc.) 

  

 The engine does not rewind 

 If the blue or red diode is lit, the controller is 

blocked until the controller is restarted (the power 

supply is turned off for 1 minute). 

  

The engine only scrolls in the 

manual mode. 

Check the cables, sensor plug connection with 

the controller. 

Check that the float sensor is clean and that it 
responds to manual lifting

 

 

  

Damp / wet fleece roll

 

 

 Device mounted too low. 

During a power failure to the circulation pump, 

the water level in the small sump may rise high 

enough to flood the fleece. 

 The engine is spinning all the 

time or it will rewind a clean roll 

 Check if the float sensor is blocked (dirt, snails), 

Check if the sensor plug is properly plugged in, 

the controller will rewind the reel for only about 5-

10 seconds and will show an error with a blue 

LED. 

  

Rother problems 

  

 
 
Please contact the service 

 

Producer: 

Tropic creations

 

33

-

340 Stary Sącz, Popowice 120, 

 

www.tropicreations.com, 

 

kontakt@tropicreations.com

 

Summary of Contents for Glamorca Roller clean 200

Page 1: ... fabric should be placed on a roll with a diameter of 50mm and after turning the motor by a full turn the non woven fabric will tighten on the motor There are 3 pieces of information on the controller green LED operation the controller after receiving the signal rewinds the roll of non woven fabric blue LED sensor blocked the controller has received too long information that the sensor is lifted a...

Page 2: ...he upper cassette after installing the roller with the motor pay special attention to whether it fits well on the handles ATTENTION the use of non original reels driver power supply sensor is associated with the loss of warranty The maximum water flow is 8000L h Solving problems Problem Cause Solution Motor fault red LED Motor fault protection has tripped This is due to solid elements that have pa...

Page 3: ...ur moteur d un tour complet le voile filtrant se resserrera sur le tambour moteur qui peut être placé à gauche ou à droite 3 6 Après avoir installé le voile sur la cassette on place le tout dans le support fixé au rebord de l aquarium ou de la cuve techhnique 7 L étape suivante consiste à connecter le capteur de niveau bague jaune le moteur bague rouge et l alimentation électrique au contrôleur qu...

Page 4: ...tallant le rouleau avec le moteur celui ci s adapte parfaitement aux poignées ATTENTION l utilisation de rouleaux de blocs d alimentation de contrôleurs et de capteurs qui ne sont pas d origine entraîne une annulation de garantie Le débit d eau maximal est de 8000 L h Problème Cause Solution Défaut moteur LED rouge La protection contre les dommages moteur a été déclenchée La cause en est des éléme...

Page 5: ...mel festgeklebt werden Wenn dann die Motortrommel um eine volle Umdrehung gedreht wird zieht sich das Filtervlies an der Motortrommel fest die links oder rechts platziert werden kann 3 6 Nachdem das Vlies in die Kassette eingelegt wurde wird das Ganze in die am Rand des Tanks oder Sumpfes angebrachte Halterung eingesetzt 7 Als nächstes werden der Füllstandssensor gelbes Band der Motor rotes Band u...

Page 6: ...pült ist dass bei der Installation der Rolle mit dem Motor dieser perfekt in die Griffe passt ACHTUNG die Verwendung von nicht originalen Rollen Controller Netzteilen und Sensoren führt zum Erlöschen der Garantie Der maximale Wasserdurchfluss beträgt 8000L h Problem Ursache Lösung Motorausfall rote LED Der Motorschadenschutz wurde ausgelöst Die Ursache sind feste Elemente die in das Sieb eingedrun...