WARNING

 

Do not store or use gasoline, or other flammable vapors and liquids, in 
the vicinity of this or any other appliance.

 

 

An LP-cylinder (Liquefied Petroleum) not connected for use shall not be 
stored in the vicinity of this or any other appliance. 

 

DANGER

 

FIRE OR EXPLOSION HAZARD 

If you smell gas: 

Shut off gas to the appliance. 
Extinguish any open flame. 
If odor continues, leave the area immediately. 
After leaving the area, call your gas supplier or fire department. 

 

Failure to follow these instructions could result in fire or explosion, 
which could cause property damage, personal injury, or death. 

 

WARNING: For Outdoor Use Only.

 

Installation and service must be performed by a qualified installer, service 

agency, or the gas supplier.

 

 
 
 

DANGER 

 
 
 
 
 

 

 
 

CARBON MONOXIDE HAZARD

 

This appliance can produce carbon 
monoxide which has no odor.

 

 

Using it in an enclosed space can kill you.

 

 

Never use this appliance in an enclosed 
space such as camper, tent, car, or home.

 

 

WARNING: 

If the information in this manual is not followed exactly, a fire or 

explosion may result causing property damage, personal injury, or loss of life.

 

Summary of Contents for 401442FP

Page 1: ...appliance DANGER FIRE OR EXPLOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues leave the area immediately After leaving the area call your gas supplier or fire department Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death WARNING For Outdoor Use Only Installation and...

Page 2: ...rvicing this equipment Some information listed in this manual has headings which have been highlighted In order to assist you in identify critical pieces of information They can be identified as follows WARNING Contains information critical to the safe installation and operation of the unit DANGER Contains information critical to the safety of you your personal property and others around this prod...

Page 3: ...Burning gas both Natural and LP produces fumes which can be dangerous if inhaled Always insure there is proper ventilation when using any fire products DANGER All Fire Pits are designed and intended for outdoor use only Never install or operate indoors Burning gas both Natural and LP produces very high temperatures Always insure all combustible materials are kept far enough away to prevent acciden...

Page 4: ... use with all types of gas Apply to all male pipe fittings only DO NOT use on FLARED fittings Be sure all joints are tightened securely before lighting WARNING Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative that ...

Page 5: ...back mounting bracket of the tank hits the back of the slot Line up the holes in the front mounting bracket and the post on the front brace then place the tank down For 401800SQ and 401800RCT models place the horizontal LP gas tank so that the back mounting bracket is in the slot and bracket hits the bumper Line up the hole in the front mounting bracket and the post on the front brace then place t...

Page 6: ... your local home improvement store and follow all directions supplied by the manufacturer WARNING Inspect the burner assembly at least every six 6 months to insure there is no damage before use Clean your burner pilot and thermocouple at least every six months to insure proper operation The spark used to ignite your Fire Pit comes from a 9 volt battery located in a Battery Case under the 9V Igniti...

Page 7: ... or death and may damage personal property The deeper your decorative glass fire pebbles or lava rock the more risk of reducing or smothering the flame from the burner Decorative Glass or Fire Pebbles Application 1 Install your Fire Pit per instructions 2 Apply decorative glass or fire pebbles just deep enough to cover bottom of pan Make sure you do NOT cover the Blow Out Box Blow Out Box 3 Blow O...

Page 8: ...press and hold the gas valve knob 4 Turn On spark igniter by depressing switch in short bursts until pilot lights 5 Once lit release switch for spark igniter while continuing to depress valve knob for 20 seconds 6 Turn knob counter clockwise left to light main burner NOTE If fails to light rotate knob to center position wait 5 minutes for gas to clear repeat Steps 3 6 If pilot goes out repeat Step...

Page 9: ...R15SP100 6 7 Nipple 3 8 x 1 5 R15SP101 7 1 2 x 1 2 FIP 90 R15CO101 8 Gas Hose with Regulator 3 8 x 12 Long R18FH100 Gas Hose with Regulator 3 8 x 36 Long R18FH103 9 3 8 Flare x 3 8 MIPT R18CO108 10 Elbow 3 8 M x 3 8 F R15CO100 11 Brass Adapter 3 8 R15CO111 12 Gas Plumbing Support Weldment W401442FPSGV Gas Plumbing Support Weldment not shown W401443FPSGV Gas Plumbing Support Weldment not shown W401...

Page 10: ...rner Tray Square 18 not shown R19NS100 5 Igniter Assembly R19NT100 6 Nut 1 2 Stainless Steel R02NU500 7 Burner Tray Round 18 R15MS300 Burner Tray Square 18 not shown R15MS301 8 Washer 1 50 OD x 0 0890 ID x 0 09 R02WA880 9 Nipple 1 2 Stainless Steel R15CO106 10 Elbow 1 2 FPT x 3 8 FPT R18CO120 11 3 8 LP Gas Air Mixer R18VL101 12 Solid Hex Socket Plug W Thread Sealant R02SC443 13 3 8 MPT x 1 8 FPT R...

Page 11: ...ly R19NT108 5 Pilot Thermocouple Assembly R19TC101 6 Igniter Assembly R19NT100 7 Burner Support R15MS309 8 Burner Tray 30 x 8 Rectangular R15MS308 9 Washer 1 Stainless Steel R02WA880 10 Nipple 1 2 Stainless Steel R15CO106 11 Elbow 1 2 FPT x 3 8 FPT R18CO120 12 3 8 LP Gas Air Mixer R18VL101 13 14 1 2 Flare x 3 8 MIP Flare Half Union R18CO107 14 3 8 FPT TEE R15CO109 15 3 8 MPT x 1 8 FPT Reducing Bus...

Page 12: ...r assembly connection beneath the burner tray When converting from LP to Natural gas installer must remove the supplied gas hose and LP regulator and install the correct regulator for Natural gas The regulator must limit the supply as specified below Natural Gas Supply Pressure Minimum 5 0 WC water column Maximum 10 0 WC Operating Pressure Minimum 5 0 WC Maximum 7 0 WC Remove the LP Gas tank hose ...

Page 13: ... this appliance is intended to use on all male threads EXCEPT compression threads Never apply thread tape of compound to compression threads Beneath the Burner tray locate the Gas Air Mixer in the plumbing Remove the LP Gas Air Mixer and replace with the Natural Gas Orifice LP Gas Air Natural Mixer Gas Orifice ...

Page 14: ...ev L 08FEB19 Once your Fire Pit has been converted to Natural Gas please locate the small silver label and remove the bottom strip Place this strip over the section indicated above on the large label located on the inside door ...

Page 15: ...R9T12FIRE Page 15 of 16 Rev L 08FEB19 This page intentially left blank ...

Page 16: ...e Pit has been tested and approved in accordance with ANSI Z21 97 by ICC ES Listing No PMG 1114 Tropitone Furniture Co Inc 5 Marconi Irvine Ca 92618 949 951 2010 www tropitone com 1401 Commerce Blvd Sarasota Fl 34243 Tropitone Furniture Co Inc 2019 ...