Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Risk of electric shock!
The device does not have the appropriate protection
class for use in wet rooms.
There is a risk of electric shock!
Never use the device in wet rooms (e.g. in bathrooms
and laundry rooms) and never immerse the device in
water!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch the device off.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Device description
The device uses the principle of condensation and a Peltier
element to dehumidify small rooms in a silent manner.
The fan sucks in damp room air through the air inlet. The room
air is cooled at the cold side of the Peltier element until it is
below the dew point. Water vapour contained in the room air
precipitates as condensation or rime. The dehumidified, cooled
air is blown out. The drier air thus conditioned mixes with the air
in the room. The humidity in the room where the device is
positioned is reduced as air constantly circulates through the
device.
Depending on the air temperature and the relative humidity, the
condensed water drops into the condensation tank. The latter is
fitted with a float to measure the filling level.
If the maximum level of the condensation tank is reached or
if the float is not correctly positioned, the indicator LED will light
up orange. The device switches off. The LED only goes out
again once the emptied condensation tank is reinserted.
The functioning of the two devices is identical, they only differ in
terms of their technical data.
Info
The TTP 10 E is additionally equipped with a removable
air filter. Instructions and notes regarding the air filter
only refer to the TTP 10 E.