background image

8

EN

dehumidifier TTP 5 E / TTP 10 E

Warning of electrical voltage

Risk of electric shock!
The device does not have the appropriate protection
class for use in wet rooms.
There is a risk of electric shock!
Never use the device in wet rooms (e.g. in bathrooms
and laundry rooms) and never immerse the device in
water!

Switching the device on

Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.

Warning of electrical voltage

Do not remove the condensation tank from the device
during operation.
The device keeps running even if the condensation
tank is not inserted!
Otherwise, water may drop from the device
uncontrollably and damage the device. There is a risk
of electric shock!

1. Press the on/off switch (1).

ð

The indicator LED (10) is illuminated in green.

ð

The fan switches on.

ð

The device starts to dehumidify.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Empty the condensation tank, if need be.

Clean the device according to the Maintenance chapter.

Store the device according to the Transport and storage
chapter.

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damage.

Check the on-site fusing.

Check the condensation tank for correct seating.

Check whether the condensation tank is full. The indicator
LED (10) is illuminated in orange.

Check the room temperature. Observe the device's
permissible ambient temperature according to the
technical data.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is running, but there is no formation of
condensate:

Check the float in the condensation tank for dirt. 
If necessary, clean the condensation tank. The float must
be able to move freely.

Check the room temperature. Observe the device's
permissible ambient temperature according to the
technical data.

Ensure that the relative room humidity complies with the
technical data.

Check the air filter for dirt. If necessary, clean or replace
the air filter.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Condensate is leaking:

Check the device for leaks.

The device gets very warm, is loud or is losing
performance:

Check the air inlets and air filters for dirt. Remove external
dirt.

From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company or by Trotec.

Note

Wait for at least 10 minutes after maintenance and
repair work. Only then switch the device back on.

The device still does not operate correctly after these
checks:

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Summary of Contents for 1105000010

Page 1: ...TRT BA TTP5E TTP10E TC220516TTRT03 005 EN TTP 5 E TTP 10 E EN OPERATING MANUAL DEHUMIDIFIER ...

Page 2: ... TTP 5 E https hub trotec com id 41289 TTP 10 E https hub trotec com id 41290 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all wa...

Page 3: ...ke sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Never insert any objects or limbs into the device Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain h...

Page 4: ...y 1 Switch the device off 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective device to the mains Information about the device Device description The device uses the principle of condensation and a Peltier element to dehumidify small rooms in a silent manner The fan sucks in dam...

Page 5: ...e depiction TTP 5 E 6 4 1 2 3 5 TTP 10 E 2 1 3 6 8 7 9 No Designation 1 On off switch LED illuminated 2 Air inlet 3 Condensation tank 4 Power adapter 5 Mains connection 6 Air outlet 7 Transport handle 8 Air filter TTP 10 E only 9 Power cable ...

Page 6: ...ther devices or objects on top of the device to prevent it from being damaged Assembly and start up Scope of delivery 1 x device 1 x Power adapter TTP 5 E 1 x Power cable TTP 10 E 1 x Power cable TTP 10 E 1 x manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and...

Page 7: ...s inserted correctly Ensure that the condensation tank V is empty and inserted correctly Connecting the power cable power adapter TTP 5 E Plug the cable s device plug into the device s mains connection TTP 5 E Plug the power adapter or power cable into a properly fused mains socket Operation Avoid open doors and windows After being switched on the device operates fully automatically Operating elem...

Page 8: ...wer cable and mains plug for damage Check the on site fusing Check the condensation tank for correct seating Check whether the condensation tank is full The indicator LED 10 is illuminated in orange Check the room temperature Observe the device s permissible ambient temperature according to the technical data Wait for 10 minutes before restarting the device If the device is not starting have the e...

Page 9: ...tank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Test run Empty and clean ...

Page 10: ...hol based or abrasive cleaners to dampen the cloth Visual inspection of the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company or by Trotec 5 Put the air filter back in Cleaning the air filter The follow...

Page 11: ...ice 4 Reinsert the air filter into the device TTP 10 E Emptying the condensation tank If the condensation tank is full the indicator LED 10 lights up orange The device switches off 1 Take the condensation tank out of the device 11 2 Remove the rubber stopper 11 from the condensation tank 3 Empty the condensation tank over a drain or sink 4 Put the rubber stopper 11 back in 5 Rinse the tank with cl...

Page 12: ...he float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on Activities required after maintenance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Transport and storage chapter ...

Page 13: ...at this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: