8
EN
dehumidifier TTP 5 E / TTP 10 E
Warning of electrical voltage
Risk of electric shock!
The device does not have the appropriate protection
class for use in wet rooms.
There is a risk of electric shock!
Never use the device in wet rooms (e.g. in bathrooms
and laundry rooms) and never immerse the device in
water!
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
Warning of electrical voltage
Do not remove the condensation tank from the device
during operation.
The device keeps running even if the condensation
tank is not inserted!
Otherwise, water may drop from the device
uncontrollably and damage the device. There is a risk
of electric shock!
1. Press the on/off switch (1).
ð
The indicator LED (10) is illuminated in green.
ð
The fan switches on.
ð
The device starts to dehumidify.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Empty the condensation tank, if need be.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Transport and storage
chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
Check the condensation tank for correct seating.
•
Check whether the condensation tank is full. The indicator
LED (10) is illuminated in orange.
•
Check the room temperature. Observe the device's
permissible ambient temperature according to the
technical data.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of
condensate:
•
Check the float in the condensation tank for dirt.
If necessary, clean the condensation tank. The float must
be able to move freely.
•
Check the room temperature. Observe the device's
permissible ambient temperature according to the
technical data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
•
Check the device for leaks.
The device gets very warm, is loud or is losing
performance:
•
Check the air inlets and air filters for dirt. Remove external
dirt.
•
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company or by Trotec.
Note
Wait for at least 10 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.