particle counter PC 200

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 3

Information about the device................................................ 4

Transport and storage........................................................... 7

Operation ............................................................................... 7

Maintenance and repair ...................................................... 11

Disposal ............................................................................... 12

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning of explosive substances

This symbol indicates dangers to the life and health of
persons due to potentially explosive substances.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

PC200

https://hub.trotec.com/?id=40285

Definitions

Term

Meaning

Differential 
(Analysis)

The device counts the effectively
measured particles per separate
channel within the set measuring
period. There is no averaging as in

concentration

 mode. Measuring in

differential

 mode is therefore more

precise.
Example: 
The measuring device shows
100 particles in the 0.3 μm channel and
30 in the 0.5 μm channel. The
differential data is 100 particles
> 0.3 μm and < 0.5 μm, and 30
particles > 0.5 μm.

Wet-bulb temperature The wet-bulb temperature is the lowest

temperature below the current
surrounding conditions which can be
reached by the evaporation of water.

Coincidence loss

When measuring high concentrations of
particles, it may happen that two
particles are so close to each other that
they are counted as one (mostly larger)
particle.

Concentration 
(Analysis)

Adding up of the measured values per
separate channel directly from the first
seconds of a measurement.
Every second of the running measuring
period the device calculates the
respective average per channel from
the determined values and the resulting
volume.

Summary of Contents for 3510006010

Page 1: ...TRT BA PC200 TC220630TTRT01 008 EN PC 200 EN OPERATING MANUAL PARTICLE COUNTER...

Page 2: ...ng manual must be observed You can download the current version of the operating manual and the EU declaration of conformity via the following link PC200 https hub trotec com id 40285 Definitions Term...

Page 3: ...autions were taken at the surveyed location e g when performing measurements along public roads on building sites etc Otherwise do not use the device Observe the storage and operating conditions see T...

Page 4: ...he particle counter sucks in air for an adjustable amount of time and determines the size and amount of particles contained in it Particles of the sizes 0 3 m 0 5 m 1 0 m 2 5 m 5 0 m and 10 0 m are tr...

Page 5: ...r the respective channel were determined on the basis of ISO 14644 1 and in connection with practical experience values They are in no way legally binding and have a merely orientating function Device...

Page 6: ...or 4 minutes Parameter Value Temperature measurement Temperature range 0 C to 50 C 32 F to 122 F Temperature accuracy 0 5 C 0 9 F at 10 C to 40 C 50 F to 104 F 1 0 C 1 8 F in other temperature ranges...

Page 7: ...ght For storing the device use the transport case included in the scope of delivery in order to protect the device from external influences the storage temperature complies with the values specified i...

Page 8: ...icator 17 Start delay Measurement duration Measurement interval 18 Indicator scale for particle burden 19 Size and amount of particles 20 Relative humidity 21 Wet bulb temperature 22 Dew point 23 Temp...

Page 9: ...ement data 3 Press the RUN STOP button Depending on the configuration start delay measurement duration and measurement interval are shown consecutively The number of measured particles and their size...

Page 10: ...TER button 4 Use the buttons to select activate to activate the filter efficiency mode activate deactivate 5 Press ESC to return to the Measurement screen 6 Press RUN STOP to start the measurement Onc...

Page 11: ...pport on that score Trotec accepts no liability concerning the use of this free software and is under no obligation to make adjustments or to further develop updates or upgrades Connecting a USB cable...

Page 12: ...otos videos and measurement logs on the internal memory or on the microSD card remain unaffected Disposal Always dispose of packing materials in an environmentally friendly manner and in accordance wi...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: