7
EN
Operating manual – air washer AW 10 S
Exchanging the SecoSan® Stick (optional)
The SecoSan
®
Stick should be exchanged approx. every 6
months. The LED display for the SecoSan
®
Stick lights up when
an exchange is required.
ü
The device is switched off and disconnected from the
mains.
ü
The upper part of the device has already been removed
from the device.
1. Remove the disk.
2. Remove the SecoSan
®
Stick and dispose of it properly.
3. If necessary, empty the water tank.
4. Insert the new SecoSan
®
Stick into one corner of the water
tank. Make sure not to block the rotating disk.
5. Refit the disk. Check the disk for complete movability. If
necessary, reposition the SecoSan
®
Stick so that the disk
can turn freely.
6. Fill the water tank with fresh drinking water.
7. Put the upper part back on the device.
After switching the device back on, you have to reset the LED
display for the SecoSan
®
Stick:
1. Press the reset button (18) with a suitable tool (e.g. paper
clip or toothpick) for approx. 3 s.
ð
The SecoSan
®
Stick indication disappears.
Cleaning the disk
ü
The device is switched off and disconnected from the
mains.
ü
The upper part of the device has already been removed
from the device.
1. In case of slight soiling, insert the Easy Kit between two of
the disks and move it back and forth.
2. In case of heavy soiling, you can disassemble the disk into
its individual components and clean them thoroughly:
Disassembling the disk
1. Take the disk out of the water tank.
2. Open the lateral screwing with the Easy Kit or with a coin by
turning the cap counter-clockwise.
3. Remove the cap.
4. You can take the disks off the shaft and clean them
individually.
5. After cleaning, slide the disks back on the shaft.
6. Put the cap back on the shaft and fasten the cap by turning
clockwise.
7. Reinsert the disk into the device. Check the disk for
complete movability. If necessary, reposition the
SecoSan
®
Stick so that the disk can turn freely.
8. Put the upper part back on the device.