multimeter BE47

Information about the device

Device description

The multimeter is a battery-powered, mobile hand-held
measuring device with an extensive range of measurement
possibilities.
It features the following functional properties and equipment:

Manual range selection

2000 count LC display

Safety category CAT II 600 V / CAT III 300 V

AC and DC voltage measurement

Direct current measurement

Resistance measurement

Diode testing function

Acoustic continuity testing

Device depiction

1

2

3

6

7

8

9

10

4

5

No.

Designation

1

Protective cover

2

Red measuring probe

3

Black measuring probe

4

Fuses

5

Battery compartment

6

V/Ω/mA connection socket

7

COM socket

8

10 A socket

9

Rotary switch

10

LC display

Rotary switch

11

12

13

14

15

16

17

No.

Position

Description

11

OFF

The device is switched off.

12

VAC

AC voltage:
up to 600 V AC
up to 200 V AC

13

ADC

Direct current:
up to 2000 µA
up to 20 mA
up to 200 mA
up to 10 A

14

BAT.

Battery voltage:
up to 1.5 V
up to 9 V

15

Diode test / continuity measurement

16

Ω

Resistance measurement:
up to 200 Ω
up to 2000 Ω
up to 20 kΩ
up to 200 kΩ
up to 2000 kΩ

17

VDC

DC voltage:
up to 200 mV DC
up to 2000 mV DC
up to 20 V DC
up to 200 V DC
up to 600 V DC

Summary of Contents for BE47

Page 1: ...TRT BA BE47 TC2015 22 001 EN BE47 EN OPERATING MANUAL MULTIMETER...

Page 2: ...he device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may r...

Page 3: ...vice when the battery compartment or the housing are open Hazardous electric current Work on the electrical components must only be carried out by an electrically skilled person or an authorised speci...

Page 4: ...on 1 2 3 6 7 8 9 10 4 5 No Designation 1 Protective cover 2 Red measuring probe 3 Black measuring probe 4 Fuses 5 Battery compartment 6 V mA connection socket 7 COM socket 8 10 A socket 9 Rotary switc...

Page 5: ...Weight 260 g 9 17 oz Dimensions 121 5 x 60 6 x 40 mm 4 78 x 2 38 x 1 57 Safety This measuring device is designed for indoor use and complies with overvoltage category CAT II 600 V CAT III 300 V pollut...

Page 6: ...before opening the battery compartment Note Make sure that the surface of the device is dry and the device is switched off 1 Remove the protective cover 1 from the device 2 Loosen the screw at the bat...

Page 7: ...the red measuring line into the V mA measuring socket 3 Connect both measuring tips to the measuring object with correct polarity black to minus red to plus If the input voltage is negative a minus w...

Page 8: ...t resistance continuity or diode measurements switch off the current of the electric circuit and discharge all capacitors 1 Select the largest resistance measuring range using the rotary switch 2 Inse...

Page 9: ...been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list Display segments are only faintly visible or flic...

Page 10: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: