digital true RMS multimeter BE52
•
Never charge batteries that cannot be recharged.
•
Different types of batteries and new and used batteries
must not be used together.
•
Insert the batteries into the battery compartment according
to the correct polarity.
•
Remove discharged batteries from the device. Batteries
contain materials hazardous to the environment. Dispose
of the batteries according to the national regulations.
•
Remove the batteries from the device if you will not be
using the device for a longer period of time.
•
Never short-circuit the supply terminal in the battery
compartment!
•
Do not swallow batteries! If a battery is swallowed, it can
cause severe internal burns within 2 hours! These burns
can lead to death!
•
If you think batteries might have been swallowed or
otherwise entered the body, seek medical attention
immediately!
•
Keep new and used batteries and an open battery
compartment away from children.
•
Disconnect the measuring cables from the device before
replacing the batteries.
•
Do not exceed the measuring range of a function specified
in the technical data.
•
Always disconnect the measuring tips from the circuit
before changing the measuring mode.
•
Proceed with the utmost care when measuring voltages
above 25 VAC rms or 35 VDC. There is a risk of an electric
shock at these voltage levels.
•
Ensure that the measuring area has zero potential and the
capacitors are discharged before you carry out diode,
resistance or continuity tests. Disconnect the measuring
lines from the measuring area before switching over the
device to diode, resistance or continuity tests if you have
previously carried out measurements on live components
Intended use
Only use the device for measurements within the measuring
ranges and overvoltage categories specified in the technical
data.
Intended use comprises:
•
measurements of AC and DC voltages
•
measurements of direct and alternating currents
•
capacitance measurements
•
frequency / duty cycle measurements
•
resistance measurements
•
testing diodes
•
acoustic continuity tests
•
Temperature measurements with external type K sensor
To use the device for its intended use, only use accessories and
spare parts which have been approved by Trotec.
Foreseeable misuse
Do not use the device in potentially explosive atmospheres,
when wet or very humid.
Unauthorized modifications of the device are forbidden.
Personnel qualifications
People who use this device must:
•
master the 5 safety rules of electrical engineering
– 1. De-energise
– 2. Secure against restart
– 3. Verify de-energised state (bipolar)
– 4. Earth and short-circuit
– 5. Cover neighbouring live parts
•
take measures to protect themselves from direct contact
with live parts.
•
have read and understood the instructions, especially the
Safety chapter.