Operating manual – 3-in-1 multi-function sander PMSS 10-200

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Troubleshooting tasks which require the housing to be opened
must only be carried out by an authorized specialist electrical
company or by Trotec.

Slight smoke or odour are emitted during first use:

This is not a fault. These phenomena disappear after a
brief runtime.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Info

Wait for at least 10 minutes before switching the
device back on.

The sanding plate does not move although the motor is
running:

Make sure that there is no workpiece debris blocking the
drive. Remove the blockages, if any.

Check whether you have mounted a sanding plate that is
suitable for this device.

The sanding plate is loose:

Check whether you have mounted a sanding plate that is
suitable for this device.

Check the sanding plate for tight fit. If necessary, tighten
the screws.

If necessary, check the rubber pins in the sanding plate for
correct fit.

The motor slows down:

Check whether the device is overloaded by the workpiece.

Reduce the pressure applied on the workpiece.

Check whether the workpiece is suitable for the tasks to
be carried out.

The surface of the workpiece is not smooth or the grinding
performance is insufficient:

Check whether the selected sanding sheet is suitable for
the material to be processed.

If the sanding sheet is worn, replace it with a new one, see
chapter Changing the sanding sheet.

Check the oscillation rate setting. It must be suitable for
both the sanding sheet and the material.

Select a higher oscillation rate by turning the setting wheel
for the oscillation rate selection to the desired level.

The sanding sheet wears off quickly:

Check whether the selected sanding sheet is suitable for
the material to be processed.

Reduce the pressure applied on the workpiece.

Select a lower oscillation rate by turning the setting wheel
for the oscillation rate selection to the desired level.

The device becomes hot:

Make sure not to exert too much pressure on the device
during operation.

Select a lower oscillation rate by turning the setting wheel
for the oscillation rate selection to the desired level.

Check whether the selected sanding sheet is suitable for
the tasks to be carried out.

Keep the venting slots clear to prevent the motor from
overheating.

Wait for 10 minutes before switching the device back on.

Notice

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Summary of Contents for EdgeProtect 4550

Page 1: ...TRT BA PMSS10 200 TC 001 EN PMSS 10 200 EN OPERATING MANUAL 3 IN 1 MULTI FUNCTION SANDER...

Page 2: ...ndicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Not permissible for wet grinding Information marked with this symbol indicates that wet grinding is...

Page 3: ...rounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There...

Page 4: ...king conditions and the work to be performed Use of the power tool for operations different from those intended could result in a hazardous situation General Power Tool Safety Warnings Service Have yo...

Page 5: ...at you stand firmly on the ground It is safer to handle the power tool with two hands Never touch the abrasive belt while it is in motion Risk of injury Do not use worn torn or heavily contaminated ab...

Page 6: ...sure that no water or other liquids can enter the housing Warning of explosive substances Fine dust produced during grinding is highly flammable Risk of fire and explosion Use a dust or chip bag or a...

Page 7: ...f the mains socket 3 Do not reconnect a defective device to the mains Information about the device Device description The device PMSS 10 200 is a 3 in 1 multi function sander for dry sanding The devic...

Page 8: ...ter 12 Tab 13 Dust box release button 14 Delta sanding plate 15 Setting wheel for oscillation rate selection Scope of delivery 1 x Device PMSS 10 200 1 x Dust collector 1 x Reducer 1 x Orbital sanding...

Page 9: ...tion The vibration level specified in these instructions was determined by means of a measuring method standardized in EN 60745 and can be used for a device comparison The specified vibration emission...

Page 10: ...storage conditions dry and protected from frost and heat ambient temperature below 40 C protected from dust and direct sunlight inside the transport case Start up Unpacking the device Take the transp...

Page 11: ...ing 21 for correct fit 21 5 When mounting the orbital sanding plate 6 or the delta sanding plate 14 insert the four rubber pins 10 into the sanding plate so that the latching noses sit in the recesses...

Page 12: ...sanding sheet can be exchanged for processing different materials Moreover available are different grain sizes for coarse to fine sanding It might be necessary to adjust the speed according to the ne...

Page 13: ...the orbital sanding plate Otherwise you cannot fix the sanding sheet in the clamping bracket Proceed as follows 1 Fold down the locking lever 5 on one side of the device to open the corresponding clam...

Page 14: ...it into the two grooves of the dust collector 11 The dust collector 11 must lock into place in the device 2 11 22 Mounting the external dust extraction system Alternatively you can also connect the du...

Page 15: ...tear and cause damage to the workpiece Exchange sanding sheets in due time Clamp the workpiece unless it is firmly and safely positioned by its own weight Do not overload the device so that it comes...

Page 16: ...medium 80 100 120 For fine and finish grinding of hard wood fine 180 240 Switching the device on and off Wear your personal protective equipment when working with the device 1 Slide the on off switch...

Page 17: ...e is suitable for the tasks to be carried out The surface of the workpiece is not smooth or the grinding performance is insufficient Check whether the selected sanding sheet is suitable for the materi...

Page 18: ...soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol...

Page 19: ...ack into the dust collector cover Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household...

Page 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: