EN
4
Operating manual – radiant heater IR 1500 S
Information about the device
Description of the device
The device
IR 1500 S
is used to quickly generate instant heat.
The device is based on the functional principle of heat
generation by infrared radiation. Persons or objects are heated
directly.
•
suitable for wet rooms
•
splash-proof IP24
•
only suitable for wall mounting
•
adjustable angle
•
no dust circulation (suitable for allergy sufferers)
Device depiction
0
0
11
2
1
5
6
7
3
4
3
No.
Designation
1
Heating rods
2
Heating level indicator:
0 = off
1 = level 1 (500 W)
2 = level 2 (1000 W)
3 = level 3 (1500 W)
3
Warning label (device must not be covered)
4
Pull switch with cord
5
Bracket for wall mounting
6
Swivelling bracket
7
Power cable
Transport and storage
Transport
Before
transporting the device, proceed as follows:
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down sufficiently.
Storage
Before
storing the device, proceed as follows:
•
Allow the device to cool down sufficiently.
When the device is not being used, observe the following
storage conditions:
•
dry and protected from frost and heat.
•
protected from dust and direct sunlight.
•
with a cover to protect it from invasive dust, if necessary.
•
Remove the batteries from the device.
•
Place no further devices or objects on top of the device
to prevent it from being damaged.
Assembly and installation
Scope of delivery
•
1 x Radiant heater
•
4 x Fastening screws
•
1 x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Assembly
The device is only suited for wall mounting. Observe the
following requirement for installation inside a room:
Danger
Risk of fire due to improper installation!
There is a risk of fire if the required minimum
distances are not observed.
The device must be positioned at a distance of at least
180 cm from the floor and at least 50 cm from walls
and other objects such as curtains or sockets.