5
EN
Operating manual – radiant heater IR 1500 S
Installation
When installing the device, observe the minimum distances
from walls and other objects as described in the Technical data
chapter.
•
Minimum distance of 180 cm from the floor.
•
Minimum distance of 50 cm from walls or other objects.
•
For installation in bathrooms or washing rooms, observe
the national regulations on safety distances.
•
Do not install the device at the ceiling or directly behind
a door.
•
Never install the device in a way that it radiates directly
onto walls or other objects.
•
Only install the device in a horizontal position.
0
0
50 cm
50 cm
180 cm
50 cm
00
00
The following is required for installation:
•
a pencil for marking the drill holes
•
a tape measure for determining the distances
•
a suitable drill
•
dowels appropriate for the structure of the wall
•
a screwdriver
•
a spirit level
1. Mark the drill holes on the wall according to the following
pattern:
117 mm
41 mm
2. Drill the holes into the wall at the marked positions.
3. Insert suitable dowels into the bore holes.
4. Insert the screws into the dowels and fasten the screws.
ð
The screws should protrude approx. 0.5 cm from the
dowels.
5. Hang the device in.
6. Check whether all 4 screws are hooked into the bracket.
7. Tilt the device to the desired angle. Ideally, the inclination
angle should be between 20° and 40°.
20° - 40°