Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Cleaning the device
Danger
Never immerse the device in water!
Caution
Do not touch the reflector or the heating rods with bare
hands.
Clean the housing with a soft, damp and lint-free cloth.
Ensure that no moisture enters the housing. Do not use any
aggressive cleaning agents such as cleaning sprays, solvents,
alcohol-based or abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Dirt on the heating rods should be removed with a long brush
with soft bristles.
Technical annex
Technical data
Parameter
Value
Model
IR 1500 S
Heating capacity (W)
500 / 1000 / 1500
Mains connection
1/N/PE ~ 230 V / 50 Hz
Nominal current (A)
6.5
Weight (kg)
1.80
Dimensions
(length x width x height in mm)
120 x 560 x 163
Plug type
CEE 7/7
Protection class
IP 24
Distances to walls / other objects
above
50 cm
below
180 cm
to the front
50 cm
to the sides
50 cm
Wiring diagram
1
2
L
N
PE
Switch
Quartz tube
3