EN
11
radiant heater IRS 2010 E
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the device
Warning of electrical voltage
Never immerse the device in water!
Warning of hot surface
Do not touch the reflector or the heating rods with bare
hands.
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Dirt on the heating rods should be removed with a long brush
with soft bristles.
Technical annex
Technical data
Parameter
Value
Model
IRS 2010 E
Heating capacity
2000 W
Mains connection
220-240 V / 50 Hz
Plug type
CEE 7/7
Cable length
1.95 m
Type of protection
IP44
Dimensions (length x width x
height)
200 x 270 x 1065 mm
Minimum distance to walls and
other objects:
A: top
B: rear
C: side
D: front
50 cm
-
50 cm
100 cm
Weight
6 kg
Remote control batteries
2 x AAA