background image

PAC 2000 E

OPERATING MANUAL

PORTABLE AIR  
CONDITIONER

EN

TR

T-BA-P

A

C2000E-

TC-001-EN

Summary of Contents for pac 2000 e

Page 1: ...PAC 2000 E OPERATING MANUAL PORTABLE AIR CONDITIONER EN TRT BA PAC2000E TC 001 EN ...

Page 2: ......

Page 3: ...ns and was tested at the factory for perfect functionality multiple times However if faults in the functionality occur and cannot be remedied with the measures in the chapter Errors and faults please get in touch with your dealer or distributor When making a warranty claim supply the device number see the rear of the device When manufacturer s instructions or legal regulations have not been follow...

Page 4: ...vice is not in use Unplug the device from the mains before starting with maintenance service or repair work Intended use Only use the portable air conditioner PAC 2000 E for cooling ventilating and dehumidifying room air indoors while adhering to and following the technical data Improper use Do not place the portable air conditioner PAC 2000 E on moist or wet ground Do not use the device outdoors ...

Page 5: ...ntrol 11 The device was designed for universal and flexible application Due to its compact dimensions it can be easily transported and used in all interior spaces The air handling unit cools the room air by withdrawing warmth The absorbed warmth is emitted to the outside via the exhaust air hose cooled air is fed to the installation site by means of a fan Device depiction Information about the dev...

Page 6: ...ositioning the device observe the minimum distance from walls or other objects as described in the chapter Technical data Put the device up in a level upright and stable position Do not create tripping hazards when laying the power cable Keep air inlets and outlets 2 4 5 and 8 as well as the exhaust air hose connection 7 free Prior to initial start up insert the batteries 2 x type AAA in the remot...

Page 7: ... see fig B 3 Attach the sealed condensation hose to the condensate outlet see fig C 4 Affix the condensation hose by means of the hose clip and snap it into the retaining clip see fig C Discharge of exhaust air The exhaust air coming from the device contains waste heat and residual moisture from the room to be cooled For this reason it is advisable to discharge the exhaust air outside into the ope...

Page 8: ...E button 23 until the DEHUMDIFICATION mode indication 18 lights up VENTILATION mode FAN The device circulates the room air there will be no cooling A target temperature cannot be set the Plus 21 and Minus 22 keys as well as the display 17 are disabled 1 Press the MODE button 23 until the VENTILATION mode indication 19 lights up Remote control The device can also be operated via the supplied remote...

Page 9: ...f various values and settings of the device 25 MODE button Setting the operating mode COOLING COOL DEHUMIDIFICATION DRY VENTILATION FAN 26 Plus key Increases the target temperature value in COOLING mode or the number of hours for the timer 27 SWING button Not available for this device 28 TIMER button By use of the timer function you can set the switch on or switch off time at 30 minute intervals f...

Page 10: ...ck the proper fit of the exhaust air hose In case of kinks bends or blockage in the hose exhaust air cannot be discharged Clear the way for the exhaust air Check the air filter for dirt If required clean the air filter see chapter Maintenance Check the minimum distance to walls or other objects Position the device a little more in the room s centre if required Check whether there are opened window...

Page 11: ...or cooling and air conditioning or by Trotec Condensate discharge In COOLING and DEHUMIDIFICATION mode condensate is formed which is mostly discharged via the exhaust air Remaining condensate accumulates at the bottom of the housing and ought to be drained on a regular basis If too much condensate accumulates the device switches off and indicates this by way of the Condensate indication 15 Additio...

Page 12: ...t damaged Reinsert the cleaned dry filters in the device in reverse order Technical data Wiring diagram A B Technical annex Parameter Value Model PAC 2000 E Cooling capacity 2 kW Dehumidification performance 0 75 l h Temperature adjustable 16 C to 30 C Air flow rate max 330 m3 h Timer adjustable 0 5 h to 24 h Electric connection 230 V 1 50 Hz Power consumption max 790 W Nominal current 3 5 A Refri...

Page 13: ...ng Manual Portable Air Conditioner PAC 2000 E 11 Exploded assembly drawing Note The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual ...

Page 14: ...62233 2008 The marking is found on the device nameplate Manufacturer Trotec GmbH Co KG Grebbener Straße 7 D 52525 Heinsberg Phone 49 2452 962 400 Fax 49 2452 962 200 E mail info trotec de Heinsberg 08 November 2014 Managing Director Detlef von der Lieck Pos no Spare part Pos no Spare part Pos no Spare part 1 Front Panel Assy 21 Water Level Switch Sub assy 41 Propeller Housing upper 2 Front Panel u...

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Page 17: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: