background image

EN

5

compressor PCPS 10-1100

Do not touch hot device parts.

 Please note that the

compressor and the lines can reach high temperatures
during operation and cause burns even after use of the
device. Allow the device to cool down after use. Wear
protective gloves to protect yourself against burns.

Always wear safety glasses and a respiratory mask
when using the blow-out gun.

 

Stirred up or blown off particles can easily be inhaled or
cause eye injuries.

Wear appropriate hearing protection during
operation.

 The sound pressure level L

pA

 of this device

amounts to 94.1 dB(A). Without appropriate hearing
protection this can cause hearing loss.

Only use accessories and feed hoses equipped with a
quick coupling. 

Feed hoses connected otherwise may accidentally come
loose and cause injuries due to whipping.

Do not directly breathe in the exhaust air coming from
the device.

 The exhaust air may contain contaminations

such as water, oil or metal particles from inside the
compressor. This can cause damages to health.

Make sure that the used socket is connected to a
circuit provided with sufficient overvoltage protection!

Please refer to the technical data for the corresponding
information. If used out of doors, the circuit should be
secured by means of a residual current device (RCD) with a
release current of maximally 30 mA.

Ensure the secure footing and stable positioning of the
device.

 During operation the compressor shall always be

placed on its rubber feet or the bottom side. Never exceed
the inclination angle of 10° (vertical pos.) or 15° (horizontal
pos.).

Intended use

Only use the device 

PCPS 10-1100

:

for inflating car tyres, bicycle tyres, inflatable toys, sports
equipment and beach items

for measuring the current pressure level of an inflatable
object

for generating compressed air for pneumatic tools

whilst adhering to the technical data.

Info

Please note that the pressure gauge is not calibrated.

We recommend using the power tool with original Trotec
accessories.

Foreseeable misuse

The device 

PCPS 10-1100

 is not intended for commercial use.

Do not use the device in continuous operation.
The device must not be used for inflating truck/tractor tyres or
other items the specified pressure of which exceeds the
maximum operating pressure of the compressor.
The device must not be used in the food sector or for
pharmaceutical and medical purposes.
Do not use the device for filling scuba tanks with compressed
air.
Any other use than the one described in the chapter "Intended
use" is regarded as reasonably foreseeable misuse.

Personnel qualifications

People who use this device must:

have read and understood the instructions, especially the
Safety chapter.

Personal protective equipment

Wear hearing protection.

Excessive noise can lead to hearing loss.

Wear eye protection. 

With it you protect your eyes from splintering, falling
and flying pieces which could cause injuries.

Wear a protective mask.

It saves you from inhaling harmful dusts generated
when processing workpieces.

Wear protective gloves.

They protect your hands from burns, crushing injuries
and skin abrasions.

Summary of Contents for PCPC 10-1100

Page 1: ...TRT BA PCPS10 1100 TC220330TTRT03 005 EN PCPS 10 1100 EN ORIGINAL INSTRUCTIONS COMPRESSOR...

Page 2: ...ormation marked with this symbol indicates that you should wear eye protection Wear a protective mask Information marked with this symbol indicates that you should wear a protective mask Wear protecti...

Page 3: ...door use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of...

Page 4: ...intained Device specific safety warnings for compressors and blow out guns Do not use the device in potentially explosive rooms or areas and do not install it there Make sure that the suction side is...

Page 5: ...ed on its rubber feet or the bottom side Never exceed the inclination angle of 10 vertical pos or 15 horizontal pos Intended use Only use the device PCPS 10 1100 for inflating car tyres bicycle tyres...

Page 6: ...and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Caution Keep a sufficient distance from heat sou...

Page 7: ...ation 1 Transport handle 2 On off switch with protective cover 3 Storage compartment for compressed air hose 4 Compressed air hose with quick coupling 5 3 fold nozzle attachments 6 Ball needle 7 Unive...

Page 8: ...Wear hearing protection Excessive noise can lead to hearing loss Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding tr...

Page 9: ...into place The compressed air gun is connected 13 21 Disconnecting the compressed air gun Warning Risk of injury due to whipping compressed air hose Disconnecting the compressed air hose while the sy...

Page 10: ...an inner diameter of 8 mm or more To connect one of the nozzles via the nozzle adapter please proceed as follows The device is switched off 1 Push the quick release lever 22 at the hose 15 of the comp...

Page 11: ...only want to check or reduce the pressure e g in a car tyre it is not necessary to switch the device on 1 Connect the device to the mains 2 Switch the device on by setting the on off switch 2 to posit...

Page 12: ...ng the on off switch 2 to position 0 Deflating If the existing pressure is too high or if the desired pressure was exceeded during inflation the excess air can be released To do so please proceed as f...

Page 13: ...em to be inflated has exceeded the ambient pressure Check the item to be inflated for leaks Check the compressed air gun for proper functioning and replace it if necessary The device is running but th...

Page 14: ...sure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to da...

Page 15: ...22 Guaranteed sound power level LWA 97 dB A Relevant EU directives 2005 88 EC 14 Dec 2005 2011 65 EU 01 07 2011 2014 30 EU 29 03 2014 Applied harmonised standards EN 1012 1 2010 EN 55014 1 2017 A11 20...