background image

14

EN

compressor PCPS 10-1100

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.

Particularly during cleaning and maintenance, make sure
that there is no residual pressure left in the system. Bleed
the system by pulling the trigger of the connected
compressed-air gun.

Wear hearing protection.

The sound pressure level L

pA

 of this device amounts to

94.1 dB(A). Wear hearing protection during all
maintenance activities requiring the device to be
switched on.

Notes on maintenance

Inside the device, there are no parts that need to be maintained
or lubricated by the user.

Cleaning

The device should be cleaned before and after each use.

Note

The device does not have to be lubricated after
cleaning.

Warning of electrical voltage

There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.

Clean the device with a soft, damp and lint-free cloth.
Make sure that no moisture enters the housing. Protect
electrical components from moisture. Do not use any
aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.

Dry the device with a soft, lint-free cloth.

Dry the bits with a soft, lint-free cloth.

Keep the ventilation openings free from dust deposits to
prevent overheating of the motor.

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. You can also find out about other return options
that apply for many EU countries on the website 
https://hub.trotec.com/?id=45090. Otherwise, please contact an
official recycling centre for electronic and electrical equipment
authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Only for United Kingdom

According to Waste Electrical and Electronic Equipment
Regulations 2013 (2013/3113) power tools that are no longer
usable must be collected separately and disposed of in an
environmentally friendly manner.

Summary of Contents for PCPC 10-1100

Page 1: ...TRT BA PCPS10 1100 TC220330TTRT03 005 EN PCPS 10 1100 EN ORIGINAL INSTRUCTIONS COMPRESSOR...

Page 2: ...ormation marked with this symbol indicates that you should wear eye protection Wear a protective mask Information marked with this symbol indicates that you should wear a protective mask Wear protecti...

Page 3: ...door use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of...

Page 4: ...intained Device specific safety warnings for compressors and blow out guns Do not use the device in potentially explosive rooms or areas and do not install it there Make sure that the suction side is...

Page 5: ...ed on its rubber feet or the bottom side Never exceed the inclination angle of 10 vertical pos or 15 horizontal pos Intended use Only use the device PCPS 10 1100 for inflating car tyres bicycle tyres...

Page 6: ...and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Caution Keep a sufficient distance from heat sou...

Page 7: ...ation 1 Transport handle 2 On off switch with protective cover 3 Storage compartment for compressed air hose 4 Compressed air hose with quick coupling 5 3 fold nozzle attachments 6 Ball needle 7 Unive...

Page 8: ...Wear hearing protection Excessive noise can lead to hearing loss Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding tr...

Page 9: ...into place The compressed air gun is connected 13 21 Disconnecting the compressed air gun Warning Risk of injury due to whipping compressed air hose Disconnecting the compressed air hose while the sy...

Page 10: ...an inner diameter of 8 mm or more To connect one of the nozzles via the nozzle adapter please proceed as follows The device is switched off 1 Push the quick release lever 22 at the hose 15 of the comp...

Page 11: ...only want to check or reduce the pressure e g in a car tyre it is not necessary to switch the device on 1 Connect the device to the mains 2 Switch the device on by setting the on off switch 2 to posit...

Page 12: ...ng the on off switch 2 to position 0 Deflating If the existing pressure is too high or if the desired pressure was exceeded during inflation the excess air can be released To do so please proceed as f...

Page 13: ...em to be inflated has exceeded the ambient pressure Check the item to be inflated for leaks Check the compressed air gun for proper functioning and replace it if necessary The device is running but th...

Page 14: ...sure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to da...

Page 15: ...22 Guaranteed sound power level LWA 97 dB A Relevant EU directives 2005 88 EC 14 Dec 2005 2011 65 EU 01 07 2011 2014 30 EU 29 03 2014 Applied harmonised standards EN 1012 1 2010 EN 55014 1 2017 A11 20...

Page 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: