background image

9

EN

Operating manual – PCPS 10-16V / PCPS 11-16V

Removing the battery

1. Detach the battery (24) from the device by pressing and

holding the unlocking button (27; I.) and pulling the battery
off the device (II.).

I.

II.

2. If required, charge the battery (24) as described in the

section 

Charging the battery

.

Checking the battery status

The battery comes with an integrated battery level indication.
The battery status is displayed as follows by the three LEDs of
the battery level indication (24a):

LED colour

Meaning

Green – Orange – Red

maximum charge / power

Orange – Red

medium charge / power

Red

weak charge – Recharge the
battery.

1. Press the button (28) on the battery (24).

ð

You can read the battery status from the battery level
indication (24a).

24a

28

Exchanging the valve adapter (cordless compressor)

Depending on the field of application, the following valve
adapters can be connected either directly to the device or via
the optional compressed-air hose (18).

No. Designation

Description

19

Presta valve adapter

To be used with Presta valves

20

Dunlop valve adapter

To be used with Dunlop valves

21

Ball needle

To be used with footballs or the
like

22

Universal adapter, short To be used with air mattresses

or the like

23

Universal adapter, long

To be used with air mattresses
or the like

Info

We recommend using the cordless compressor with
connected compressed-air hose.

1. Unscrew the union nut (9).

29

30

9

18

2. Insert either the (optional) compressed-air hose (18) with

its connector side (30) or the valve adapter (19, 20, 21, 22,
23) by rotating it clockwise.

3. Retighten the union nut (9).

ð

If you want to use the valve adapter (19, 20, 21, 22, 23)

without

 compressed-air hose, the valve adapter is now

fully mounted.

ð

If you want to use the valve adapter (19, 20, 21, 22, 23)

with

 compressed-air hose, please proceed with the

following steps.

Summary of Contents for PCPS 10-16V

Page 1: ...TRT BA PCPS10 16V PCPS11 16V TC 001 EN PCPS 10 16V PCPS 11 16V EN OPERATING MANUAL...

Page 2: ...ith this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed Wear ear protection Info...

Page 3: ...pment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Prevent unintentional starting Ensure the switch is in the of...

Page 4: ...tery packs may create a risk of injury and fire When battery pack is not in use keep it away from other metal objects like paper clips coins keys nails screws or other small metal objects that can mak...

Page 5: ...ialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket and the battery from the device Hold onto the mains plug while pulling the power...

Page 6: ...omatically The cordless air pump PCPS 11 16V is suited for inflating and deflating inflatable products with a large volume such as air mattresses or rubber dinghies Device depiction Cordless compresso...

Page 7: ...ments for air pump 2 x Universal adapter short 1 x Universal adapter long 1 x Transport case 1 x Manual Technical data Parameter Value Model PCPS 10 16V PCPS 11 16V Nominal voltage 16 V 16 V Max press...

Page 8: ...mains socket Allow the device to cool down Remove the battery from the device The supplied Li ion batteries are subjects to the requirements of dangerous goods legislation Observe the following when t...

Page 9: ...es below 10 C or above 40 C The battery is partially charged upon delivery to avoid damage to the battery caused by a deep discharge Prior to initial start up and when the battery is low only the red...

Page 10: ...ld of application the following valve adapters can be connected either directly to the device or via the optional compressed air hose 18 No Designation Description 19 Presta valve adapter To be used w...

Page 11: ...connected to the air inlet or air outlet No Description 31 To be used with inflatables fitted with a vent valve 32 To be used with inflatables fitted with a screw on valve venting with the valve deta...

Page 12: ...this value amounts to 0 2 Press and hold the plus 37 or minus 35 button for approx 2 s The segment display 38 flashes 3 Use the plus 37 and minus 35 buttons to set the desired pressure value 4 Wait un...

Page 13: ...Tips and notes on handling the cordless air pump General information Keep the venting slots clear to prevent the motor from overheating The device is not suitable for continuous operation The device...

Page 14: ...following list Troubleshooting tasks which require the housing to be opened must only be carried out by an authorized specialist electrical company or by Trotec Slight smoke or odour are emitted durin...

Page 15: ...s plug or the battery with wet or damp hands Switch off the device Allow the device to cool down completely Remove the battery from the device Warning of electrical voltage Maintenance tasks which req...

Page 16: ...site www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent nega...

Page 17: ......

Page 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: