background image

EN

14

Operating manual – PCPS 10-16V / PCPS 11-16V

The device is running, but there is no apparent inflation/
deflation:

Check the connections for tightness. Air might be escaping
at the valve of the inflatable object.

The device becomes hot:

Notice

The device is not suitable for continuous operation. To
prevent overheating, the device must not be used non-
stop for more than 10 minutes (

PCPS 10-16V

) or

20 minutes (

PCPS 11-16V

).

Should the device be overheating nonetheless, remove
the battery.
Allow the device to cool down sufficiently before
switching it back on.

Check whether the device is suitable for the tasks to be
carried out.

Keep the venting slots or air inlet and outlet clear to
prevent the motor from overheating.

Notice

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug or the battery with wet or
damp hands.

Switch off the device.

Allow the device to cool down completely.

Remove the battery from the device.

Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.

Notes on maintenance

Inside the device, there are no parts that need to be maintained
or lubricated by the user.

Cleaning

The device should be cleaned before and after each use.

Notice

The device does not have to be lubricated after
cleaning.

Warning of electrical voltage

There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.

Clean the device with a soft, damp and lint-free cloth.
Ensure that no moisture enters the housing. Protect
electrical components from moisture. Do not use any
aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.

Dry the device with a soft, lint-free cloth.

Dry the bits with a soft, lint-free cloth.

Keep the connecting terminals on the device and charger
clean.

Keep the connecting terminals on the battery pack clean.

Keep the ventilation openings free from dust deposits to
prevent overheating of the motor.

Summary of Contents for PCPS 10-16V

Page 1: ...TRT BA PCPS10 16V PCPS11 16V TC 001 EN PCPS 10 16V PCPS 11 16V EN OPERATING MANUAL...

Page 2: ...ith this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed Wear ear protection Info...

Page 3: ...pment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Prevent unintentional starting Ensure the switch is in the of...

Page 4: ...tery packs may create a risk of injury and fire When battery pack is not in use keep it away from other metal objects like paper clips coins keys nails screws or other small metal objects that can mak...

Page 5: ...ialist company Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket and the battery from the device Hold onto the mains plug while pulling the power...

Page 6: ...omatically The cordless air pump PCPS 11 16V is suited for inflating and deflating inflatable products with a large volume such as air mattresses or rubber dinghies Device depiction Cordless compresso...

Page 7: ...ments for air pump 2 x Universal adapter short 1 x Universal adapter long 1 x Transport case 1 x Manual Technical data Parameter Value Model PCPS 10 16V PCPS 11 16V Nominal voltage 16 V 16 V Max press...

Page 8: ...mains socket Allow the device to cool down Remove the battery from the device The supplied Li ion batteries are subjects to the requirements of dangerous goods legislation Observe the following when t...

Page 9: ...es below 10 C or above 40 C The battery is partially charged upon delivery to avoid damage to the battery caused by a deep discharge Prior to initial start up and when the battery is low only the red...

Page 10: ...ld of application the following valve adapters can be connected either directly to the device or via the optional compressed air hose 18 No Designation Description 19 Presta valve adapter To be used w...

Page 11: ...connected to the air inlet or air outlet No Description 31 To be used with inflatables fitted with a vent valve 32 To be used with inflatables fitted with a screw on valve venting with the valve deta...

Page 12: ...this value amounts to 0 2 Press and hold the plus 37 or minus 35 button for approx 2 s The segment display 38 flashes 3 Use the plus 37 and minus 35 buttons to set the desired pressure value 4 Wait un...

Page 13: ...Tips and notes on handling the cordless air pump General information Keep the venting slots clear to prevent the motor from overheating The device is not suitable for continuous operation The device...

Page 14: ...following list Troubleshooting tasks which require the housing to be opened must only be carried out by an authorized specialist electrical company or by Trotec Slight smoke or odour are emitted durin...

Page 15: ...s plug or the battery with wet or damp hands Switch off the device Allow the device to cool down completely Remove the battery from the device Warning of electrical voltage Maintenance tasks which req...

Page 16: ...site www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent nega...

Page 17: ......

Page 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: