background image

15

EN

Operating manual – cordless rotary hammer PRDS 10-20V

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Troubleshooting tasks which require the housing to be opened
must only be carried out by an authorized specialist electrical
company or by Trotec.

Slight smoke or odour are emitted during first use:

This is not a fault. These phenomena disappear after a
brief runtime.

The battery does not charge:

Check whether the battery is correctly connected to the
quick charger.
Slide the battery into the quick charger in a way that the
battery terminals engage in the quick charger. The battery
must lock in place in the quick charger.

Check the power connection.

Check the power cable and mains plug for damages.

Check the fuse (home).

Check the quick charger for damages. Should the quick
charger be damaged, stop using it. Contact the Trotec
customer service.

Check the battery terminals for dirt. Remove any dirt.

The battery might be defective and have to be replaced.
Only use batteries of the same type.

The device does not start:

The battery power might be too low. Recharge the battery.

Check whether the battery is correctly connected to the
device.
Slide the battery onto the device in a way that the battery
terminals engage. The battery must lock in place in the
device.

Check the position of the clockwise/counter-clockwise
rotation switch. The switch must be pressed in all the way.
If the clockwise/counter-clockwise rotation switch is in
centre position (lock), the on/off switch is blocked.

Check the battery terminals for dirt. Remove any dirt.

Info

Wait for at least 10 minutes before switching the
device back on.

The on/off switch cannot be pressed:

Check whether the clockwise/counter-clockwise rotation
switch is in centre position (lock). Set the desired rotational
direction to unlock the tool.

The drill bit does not penetrate / hardly penetrates the
material:

Check whether the correct operating mode is selected. The
setting for drilling   or hammer drilling 

 

 

 should be

selected.

Check whether the correct drill bit is selected.

Check whether the device is set to counter-clockwise
rotation. For drilling, it is necessary to switch over to
clockwise rotation.

The device becomes hot:

Check whether the tool is suitable for the tasks to be
carried out.

Keep the venting slots clear to prevent the motor from
overheating.

Select a lower speed.

Info

Wait for at least 10 minutes before switching the
device back on.

Notice

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Summary of Contents for PRDS 10-20V

Page 1: ...TRT BA PRDS10 20V TC 002 EN PRDS 10 20V EN OPERATING MANUAL CORDLESS ROTARY HAMMER...

Page 2: ...r moderate injury Notice This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks q...

Page 3: ...tric shock Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the r...

Page 4: ...other battery packs may create a risk of injury and fire When battery pack is not in use keep it away from other metal objects like paper clips coins keys nails screws or other small metal objects th...

Page 5: ...t of the power tool upon switch on and lead to injuries Before switching on the power tool ensure that the insertion tool can move freely If the device is switched on with a jammed insertion tool the...

Page 6: ...voltage There is a risk of a short circuit due to liquids penetrating the housing Do not immerse the device and the accessories in water Make sure that no water or other liquids can enter the housing...

Page 7: ...escription The cordless rotary hammer PRDS 10 20V comes equipped with a hammer mechanism for high impact power and is suitable for mobile use The infinitely variable impact rate and speed control allo...

Page 8: ...on 6b Battery holder 7 SDS drill bit 8 Bits 9 HSS drill bit 10 SDS bit adapter 11 Extension with magnetic bit holder 12 Quick charger 13 LED work lamp 14 Dust protection cap Scope of delivery 1 x Cord...

Page 9: ...the exposure Caution Vibration emissions can cause a health hazard if the device is used for an extended period of time or if it is not properly handled and maintained The vibration level will change...

Page 10: ...arged batteries can lead to a deep discharge and thus damage the battery When the device is not being used observe the following storage conditions dry and protected from frost and heat ambient temper...

Page 11: ...ockwise rotation 3 to centre position lock 2 Slide the battery 6 onto the device until it locks in place 6 17 Removing the battery 1 Set the switch for clockwise counter clockwise rotation 3 to centre...

Page 12: ...elivery allows you to use standard bits In addition you can fit the SDS adapter with the extension with magnetic bit holder 11 contained in the scope of delivery Please proceed as follows to use the S...

Page 13: ...y also be used for drilling in plastic Drilling in wood Use drill bits suitable for wood Place a block of wood under the workpiece or drill in from both sides so that the wood cannot break off when it...

Page 14: ...ing it away Selecting the operating mode The function selector switch 2 is used to select drilling or hammer drilling Notice Only actuate the function selector switch when the device is at a standstil...

Page 15: ...lock the on off switch 4 Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Set the switch for clockwise counter clockwise rotation 3 to centre position lock Hol...

Page 16: ...that the battery terminals engage The battery must lock in place in the device Check the position of the clockwise counter clockwise rotation switch The switch must be pressed in all the way If the cl...

Page 17: ...t free cloth Dry the bits with a soft lint free cloth Remove any drilling dust and if applicable wood chips from the SDS tool holder Keep the connecting terminals on the device and charger clean Clean...

Page 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...