12 / 53
8018_SP1500
V2.2_EN (03/2018)
4.7 Laser Safety
Laser class
CDRH Laser Safety; CE tested
Laser class 2
Interlock
Dual interlock safety system
4.8 Ambient Conditions
Prescribed ambient temperature of +15° to +25°C (+59° to +77°F)
Humidity of 40% to max. 70%, no condensation,
dust-free environment (2nd degree per IEC60947-1)
4.9 Options
CCD-camera
Registration marks and compensation system „i-Cut“;
max. working area: 1100 x 700 mm (43 x 27.5 in)
Gas-Kit (for compressed air
respectively process gas)
Considered for control of compressed air and process
gas (free of mechanical dust, water and oil) max. flow
rate 150 l/min (40 gpm) with max. 10 bar (145 psi) max.
limit 4 bar on working head push fitting connection with
out diameter) connection on the machine with hose out
diameter of 6mm (0.23 in) resp. standard fitting for
compressed air.
Vacuum table
Strong vacuum effect for thin or corrugated materials
(3500 m³/h at 500 Pa)
TroCAM
(refer to TroCAM brochure)
CAD / CAM software for perfect cutting results;
inclusively nesting-function, lead-in/lead-out, tool paths
Extraction System lead /follow-
up time
Lead- and follow-up time fully adjustable
Summary of Contents for SP1500