8
EN
electric heater TDE 25 / TDE 65 / TDE 95
•
Make sure that extension cables are completely unrolled.
•
Make sure that no curtains or other objects interfere with
the air flow.
•
Make sure that the device cannot come into contact with
moisture or water.
Connecting the power cable
Warning
Do not use mains cables longer than 2 m.
If the mains cable is too long or slips out of the mains
connection, there is a risk of electric shock and trip
hazard.
Also make sure that the mains connection corresponds
to the device and that the earthing must be extended. It
is recommended to use a connection constructed in
accordance with the national regulations (VDE in
Germany).
Note
Note that the device
TDE 25
switches on immediately
after connecting the power cable.
The devices
TDE 65
and
TDE 95
only switch on
immediately if the selection switch
ventilation and
heating levels
(
7
) is not set to
0
.
•
Insert the mains plug into a properly fused mains socket.
•
Make sure that the power cable is guided along the back
of the device. Never guide the power cable along the front
of the device!
Operation
•
Avoid open doors and windows.
Control panel – TDE 65 / TDE 95
7
8
9
10
11
12
No. Designation
TDE 65 / 95
7
Selection switch
ventilation
and heating levels
Switching the device on/off
Setting the heating level
8
Position
0
The device is switched off.
9
Position
1
Ventilation (no temperature
increase)
10
Position
2
Heating level 50 %
11
Position
3
Heating level 75 %
12
Position
4
Heating level 100 %
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
TDE 65 / TDE 95
1. Set the selection switch
ventilation and heating levels
(
7
)
to the desired position (position
1
– position
4
).
ð
As soon as the room has reached the required
temperature, the device stops heating and the fan
continues to run. Once the temperature drops again, the
device restarts heating. This way, the temperature is
kept at a constant level.
2. Set the selection switch
ventilation and heating
(
7
) to the
0
position to switch the device off again.
TDE 25
1. Insert the mains plug.
ð
The device is running continuously.