background image

Operating Manual – Electric hot air generator

EN

2

MANUAL RESETTING

The appliance comes with a built 
in security device that goes off au-
tomatically if the appliance should 
happen to overheat.
If the security device should go off, 

let the appliance cool down before looking for the 
cause of the problem. Push the “RESET” button with a 
small push rod to reset the appliance.
Should the problem persist, contact the Service Centre.

PERIODIC STORAGE AND CONTROL

If the appliance is not used for a long period of time, it 
should be cleaned before being put away. Store it in a 
dry place and protect it from dust. When the appliance 
is used again check to make sure that the electric 
cable is not damaged. Should you have any doubts as 
to the conditions of the appliance please contact the 
Service Center.
The appliance should be checked at least once a year. 
Only qualified personnel authorized by the manufac-
turer must carry out all repairs.

TECHNICAL DATA

Capacity  . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,5-9 kW
Absorbed current  . . . . . . . . . . . . . . . . . . . . . . . .13 A
Voltage  . . . . . . . . . . . . . . . . . . . . . . . . . 400~V/50Hz
Air displacement . . . . . . . . . . . . . . . . . . . . 708 m3/h
Thermostat range  . . . . . . . . . . . . . . . . . . . . . 0-40 °C
Size (mm)  . . . . . . . . . . . . . . . . . . . . . . 290x360x520
Weight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,3 kg

SINGLING OUT PROBLEMS

 PROBLEM: 

CAUSE: 

SOLUTION:

  The appliance works 

Resistance is burnt out 

Replace 

 

  but does not heat. 

Thermostat control is broken 

Replace

  The appliance does  

Security device was set off 

Push “RESET” 

  not switch on. 

Faulty motor 

Replace 

   

 

Power supply interrupted 

Unplug the appliance and check connection.

  Limited air flow  

Air duct obstructed 

Clear the passage 

 

   

 

Faulty motor 

Replace

RESET