The fan is not running:
•
Check whether the device is switched on.
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.
The air current is reduced:
•
Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.
The device is loud or is losing performance:
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
•
Wait for at least 3 minutes before switching the device
back on.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
The device does not respond to the infrared remote control:
•
Check whether the distance between remote control and
device is too large and reduce it if necessary.
•
Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.
•
Check the charging status of the batteries and change
them if required.
•
If the batteries have just been changed, check them for
correct polarity.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the
device cleaned by a specialist electrical company or by
Trotec.