EN
9
dehumidifier TTK 33 E
No.
Designation
Meaning
20
Mode
button
Changing the operating mode
21
Humidity
button
For setting the desired relative
humidity level
22
Segment display
Indicates the relative humidity
level, the current humidity level
and the number of hours of the
timer
23
Speed
button
For setting the desired fan
speed (function for drying
laundry)
24
Self-cleaning function
button
Switching the self-cleaning
function on or off
25
Timer
button
For switching the timer
function on and off: 1 h to 24 h
Colour LED for current room humidity
Regardless of the operating mode, the colour LED (
4
) indicates
the current relative room humidity by means of 3 different
colours.
If you press the
Mode
button (
20
) and the
Humidity
button (
21
)
simultaneously, you can switch off the colour LED (
4
).
LED colour
Meaning
Blue
Relative room humidity below 40 %
Green
Optimal relative room humidity between 40 %
and 60 %
Red
Illuminated: relative room humidity is equal to/
or above 60 %; Flashing: water tank is full
(accompanied by an acoustic signal)
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
1. Press the
Power
button (
19
).
ð
The On/off LED (
18
) is illuminated.
ð
The
Auto
LED (
17
) and the
Low
LED (
13
) are illuminated
when you switch on the device for the first time.
Operating modes
•
Automatic operation
•
Continuous operation
Setting the operating mode
1. Repeatedly press the
Mode
button (
20
) to change the
operating mode.
ð
In continuous operation mode, the
Continuous
LED (
16
)
is illuminated.
ð
In automatic operation mode, the
Auto
LED (
17
) is
illuminated.
Automatic operation
The device dehumidifies the air continuously until the set
relative humidity level is reached.
Please proceed as follows to adjust the desired humidity value:
1. Repeatedly press the
Humidity
button (
21
).
ð
The selected humidity value is indicated on the segment
display (
22
).
ð
The colour LED (
4
) is illuminated depending on the room
humidity level.
This operating mode can also be used for drying laundry. To do
so, select the highest fan speed and observe the recommended
humidity values listed under laundry drying.
Continuous operation
Regardless of the humidity level, the device dehumidifies
continuously.
In continuous operation, only the fan speed can be manually
selected.
The current humidity level is indicated on the
segment display (
22
) and the colour LED (
4
) is illuminated
depending on the room humidity level.
Info
For continuous operation a condensation drain hose
can be connected in order to continuously drain the
accumulating condensate.
Setting the fan speed
You can change between low and high fan speed.
1. Press the
Fan speed
button (
23
).
ð
If the fan speed is set to a low level, the
Low
LED (
13
) is
illuminated.
ð
If the fan speed is set to a high level,
the
High
LED (
14
, laundry drying function) is illuminated.
Auto stop function
Once the condensation tank is full, the device will stop
automatically. The
Condensation tank full
LED (
15
) is
illuminated. Empty the condensation tank as described in
section
Emptying the condensation tank
.