background image

EN

3

axial fan TTV 4500 / TTV 4500 HP / TTV 7000

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Observe a minimum distance of 3 m between walls,
objects and the suction side.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.

Make sure that the air inlet and outlet are not obstructed.

Make sure that there are no loose items or dirt located in
the immediate surroundings of air inlet and air outlet.

Protect yourself and your environment from whirled up
parts.

Improper installation can lead to a fire, electric shock or
severe personal injury.

Intended use

The axial fan 

TTV 4500

 / 

TTV 4500 HP

 / 

TTV 7000

 may be used

for aeration, deaeration, air circulation, dust collection or air
transport whilst adhering to the technical data and the safety
instructions.
The device was designed for the generation of a powerful,
large-volume air circulation, e.g. for the accelerated drying of
buildings and rooms. The fan can be operated in combination
with different accessories.

Improper use

The axial fan 

TTV 4500

 / 

TTV 4500 HP

 / 

TTV 7000

 is not suited

for installation in fluids or on flooded or boggy grounds.
Any unauthorised changes, modifications or alterations to the
device are forbidden.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when using high-
performance fans.

have read and understood the instructions, especially the
Safety chapter.

Summary of Contents for TTV 4500

Page 1: ...TRT BA TTV4500 TTV4500HP TTV7000 TC2015 47 004 EN TTV 4500 TTV 4500 HP TTV 7000 EN ORIGINAL INSTRUCTIONS AXIAL FAN ...

Page 2: ...e risk level which if not avoided can result in serious injury or death Caution This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Note This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quickly and safely Foll...

Page 3: ...echnical data Insert the mains plug into a properly secured mains socket Observe the technical data when selecting extensions to the power cable Completely unroll the extension cable Avoid electrical overload Before carrying out maintenance care or repair work on the device remove the mains plug from the mains socket Hold onto the mains plug while doing so Switch the device off and disconnect the ...

Page 4: ...tlet Caution Keep a minimum distance of 3 m to the suction side of the device Note Do not use abrasive cleaners or solvents to clean the device Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect it from the mains 2 Remove persons from the danger area 3 Do not reconnect a defective device to the mains Informatio...

Page 5: ...he mains plug while pulling the power cable out of the mains socket To make the device easier to transport it is fitted with a transport loop Do not use the power cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Storage When the device is not being used observe the following storage conditions dry and protected fr...

Page 6: ...e the condensate plug safely as it must be reinserted for cleaning and maintenance work 1 Remove the condensate plug 8 Start up When positioning the device observe the minimum distance from walls or other objects as described in the Technical data chapter A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer...

Page 7: ...TV 4500 TTV 4500 HP Designation Article number Hose adapter 6 100 005 010 Combination distributor 6 100 005 011 Dust bag class M length 3 m 7 160 000 110 Dust bag class M length 5 m 7 160 000 112 Air transport hose Tronect SP T length 7 6 m 6 100 001 214 Air transport hose Tronect TF L length 5 m 6 100 001 115 Universal lashing strap 6 100 001 995 TTV 7000 Designation Article number Hose adapter 6...

Page 8: ...for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical company or to Trotec for repair Maintenance Activities required before starting maintenance Warning of electrical voltage Do not touch the...

Page 9: ...a 100 Pa Max transport medium temperature 45 C 45 C 45 C Mains connection 1 N PE 230 V 50 Hz 1 1 A 1 N PE 230 V 50 Hz 1 4 A 1 N PE 230 V 50 Hz 1 8 A Power consumption 0 25 kW 0 33 kW 0 41 kW Fusing 10 A 10 A 10 A Type of protection IP 55 IP 55 IP 55 Max sound level distance 3 m 53 dB A 64 dB A 58 dB A Mobility portable stackable portable stackable portable stackable Hose connection with hose adapt...

Page 10: ...2 rubber feet back TTV4500 7300001246 3 rubber feet front TTV4500 7300001245 4 housing TTV4500 HP 7310000936 5 safety clamp grid BVVP0023 TTV series 7310000642 6 safety grid airoutlet TTV4500 7242000639 7 safety grid airinlet TTV4500 7242000638 8 fixing knob TTV series 7310000710 9 condensator 6μF motor TTV 7140000357 10 motor 4E40 TTV4500 7110000635 11 connector assembly kit TTV series 7320001271...

Page 11: ...he components mentioned in these instructions Spare parts list TTV 7000 No Spare part Article number 01 Wire guard impeller side 7242000646 02 Wire guard motor side 7242000645 03 Motor 7110000637 04 Bracket 05 Impeller 7310000633 06 Housing set 2 pieces 7310000939 Ventilator 7310000938 Motor 07 Frame 7240000939 08 Controller under cap 10 Condense plug 7300001248 on request ...

Page 12: ...the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 42498 Declaration of conformity In accordance with the EC Machinery Directive 2006 42 EC Annex II part 1 Section A Herewith we Trotec GmbH Co KG declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Mac...

Page 13: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...