background image

4

EN

axial fan TTV 4500 / TTV 4500 HP / TTV 7000

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Caution

Risk of injury due to parts being whirled up by the
strong air current.
Before switching the device on, make sure that there
are no loose parts (clothing, hair etc.) located near the
air inlet or outlet!

Caution

Keep a minimum distance of 3 m to the suction side of
the device!

Note

Do not use abrasive cleaners or solvents to clean the
device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains

feed-in: Switch the device off and disconnect it from the
mains.

2. Remove persons from the danger area.
3. Do not reconnect a defective device to the mains.

Information about the device

Device description

The axial fan TTV 4500 / TTV 4500 HP / TTV 7000 was designed
for a very high air flow; the TTV 4500 HP was additionally
designed for particularly high air pressure even over long air
transport distances.
The device is rated with IP55 type of protection and is thus
suitable for application both inside rooms and outdoors.
The fan speed can be set to one of 3 stages.
Depending on the type, the devices can be expanded with a
range of accessories. For example, one or two hose adapters
may be used for connecting air transport hoses and/or dust
bags. Furthermore, some device sizes allow the connection of a
combination distributor e. g. for air distribution with up to eight
hoses.

Summary of Contents for TTV 4500

Page 1: ...TRT BA TTV4500 TTV4500HP TTV7000 TC2015 47 004 EN TTV 4500 TTV 4500 HP TTV 7000 EN ORIGINAL INSTRUCTIONS AXIAL FAN ...

Page 2: ...e risk level which if not avoided can result in serious injury or death Caution This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Note This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quickly and safely Foll...

Page 3: ...echnical data Insert the mains plug into a properly secured mains socket Observe the technical data when selecting extensions to the power cable Completely unroll the extension cable Avoid electrical overload Before carrying out maintenance care or repair work on the device remove the mains plug from the mains socket Hold onto the mains plug while doing so Switch the device off and disconnect the ...

Page 4: ...tlet Caution Keep a minimum distance of 3 m to the suction side of the device Note Do not use abrasive cleaners or solvents to clean the device Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect it from the mains 2 Remove persons from the danger area 3 Do not reconnect a defective device to the mains Informatio...

Page 5: ...he mains plug while pulling the power cable out of the mains socket To make the device easier to transport it is fitted with a transport loop Do not use the power cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Storage When the device is not being used observe the following storage conditions dry and protected fr...

Page 6: ...e the condensate plug safely as it must be reinserted for cleaning and maintenance work 1 Remove the condensate plug 8 Start up When positioning the device observe the minimum distance from walls or other objects as described in the Technical data chapter A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer...

Page 7: ...TV 4500 TTV 4500 HP Designation Article number Hose adapter 6 100 005 010 Combination distributor 6 100 005 011 Dust bag class M length 3 m 7 160 000 110 Dust bag class M length 5 m 7 160 000 112 Air transport hose Tronect SP T length 7 6 m 6 100 001 214 Air transport hose Tronect TF L length 5 m 6 100 001 115 Universal lashing strap 6 100 001 995 TTV 7000 Designation Article number Hose adapter 6...

Page 8: ...for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical company or to Trotec for repair Maintenance Activities required before starting maintenance Warning of electrical voltage Do not touch the...

Page 9: ...a 100 Pa Max transport medium temperature 45 C 45 C 45 C Mains connection 1 N PE 230 V 50 Hz 1 1 A 1 N PE 230 V 50 Hz 1 4 A 1 N PE 230 V 50 Hz 1 8 A Power consumption 0 25 kW 0 33 kW 0 41 kW Fusing 10 A 10 A 10 A Type of protection IP 55 IP 55 IP 55 Max sound level distance 3 m 53 dB A 64 dB A 58 dB A Mobility portable stackable portable stackable portable stackable Hose connection with hose adapt...

Page 10: ...2 rubber feet back TTV4500 7300001246 3 rubber feet front TTV4500 7300001245 4 housing TTV4500 HP 7310000936 5 safety clamp grid BVVP0023 TTV series 7310000642 6 safety grid airoutlet TTV4500 7242000639 7 safety grid airinlet TTV4500 7242000638 8 fixing knob TTV series 7310000710 9 condensator 6μF motor TTV 7140000357 10 motor 4E40 TTV4500 7110000635 11 connector assembly kit TTV series 7320001271...

Page 11: ...he components mentioned in these instructions Spare parts list TTV 7000 No Spare part Article number 01 Wire guard impeller side 7242000646 02 Wire guard motor side 7242000645 03 Motor 7110000637 04 Bracket 05 Impeller 7310000633 06 Housing set 2 pieces 7310000939 Ventilator 7310000938 Motor 07 Frame 7240000939 08 Controller under cap 10 Condense plug 7300001248 on request ...

Page 12: ...the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 42498 Declaration of conformity In accordance with the EC Machinery Directive 2006 42 EC Annex II part 1 Section A Herewith we Trotec GmbH Co KG declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Mac...

Page 13: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: