axial fan TTV 4500 / TTV 4500 HP / TTV 7000
Operation
Operating elements
TTV 4500 / TTV 4500 HP / TTV 7000
3
2
1
0
9
10
No.
Designation
Meaning
9
Fan stage
selection switch
1
2
3
Setting the fan speed:
stage 1 = low
stage 2 = medium
stage 3 = high
10
Stage 0
Device switched off
Switching the device on
ü
The device has been completely installed as described in
the Assembly and start-up chapter.
1. Switch the device on by turning the
fan stage
selection
switch (9) to the desired position.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Switch the device off by turning the
fan stage
selection
switch (9) to the 0 position.
2. Hold onto the mains plug while pulling the power cable out
of the socket.
3. Clean the device according to the Maintenance chapter.
4. Store the device according to the Storage chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
TTV 4500 / TTV 4500 HP
Designation
Article number
Hose adapter
6.100.005.010
Combination distributor
6.100.005.011
Dust bag class M, length: 3 m
7.160.000.110
Dust bag class M, length: 5 m
7.160.000.112
Air transport hose Tronect SP-T,
length: 7.6 m
6.100.001.214
Air transport hose Tronect TF-L,
length: 5 m
6.100.001.115
Universal lashing strap
6.100.001.995
TTV 7000
Designation
Article number
Hose adapter
6.100.005.020
Dust bag class M, length: 5 m
7.160.000.112
Air transport hose Tronect SP-T,
length: 7.6 m
6.100.001.217
Universal lashing strap
6.100.001.995
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The fan is not running:
•
Check whether the device is switched on.
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
The fan operates only for a brief period, then switches off:
•
Check whether the protective grid at the air inlet is
obstructed in some way. If applicable, remove foreign
objects.
•
The motor bearing might be damaged. Please contact the
customer service.
The motor or fan is noisy or runs unevenly:
•
The fan is soiled. Clean the fan according to the
Maintenance chapter.