Pull the brake bracket assembly towards the cable guide
3.
roller and unhook the auger cable “Z” fitting. See Figure
7-5.
From both sides of the the frame assembly, use a 1/2”
4.
wrench to remove the three hex tap screws securing the
frame to the auger housing assembly. See Figure 6-8.
NOTE: Do not remove the lower hex flange lock nut on
each side.
Place a block of wood underneath the auger housing as
5.
shown in Figure 7-6 and separate auger housing from the
frame by tilting the housing forward and pulling up the
handles.
a. Block the impeller with a piece of wood to prevent
6.
if from spinning and use a 1/2” wrench to remove
the hex screw and washer from the center of the
pulley on the auger housing. See Figure 7-7.
b.
Lift the brake bracket assembly out of the pulley
groove and slide the pulley assembly off the posts
of the auger pulley adapter to remove the old belt.
Refer to Figure 7-8.
NOTE: The pulley adapter may slide off the auger input
shaft when removing the pulley. Use extra caution to
ensure the adapter does fall and/or get damaged when
removing the pulley.
Figure 7-7
Figure 7-5
Z-fitting
Figure 7-6
Screws
Figure 7-8
A
C
B
Adapter Post
Belt Keeper
Pulley Slot