6.
5-way Binding Posts:
Connect your subwoofer here.
Minimum impedance of the load is 4 ohms. Multiple
subwoofers can be connected if the combined load
impedance is 4 ohms or greater.
7.
Voltage Selector Switch:
The amplifier can be
used on 110~120V (60Hz) or 220~240V (50Hz) line
voltage. To change the operating line voltage, turn
the power off using the power button and unplug
the power cord. Remove the plastic cover screws
and the plastic cover over the voltage selector
located on the rear of the amp. Set the switch to the
correct position for the line voltage in your country.
Replace the plastic cover and screws over the
voltage selector switch.
NOTE:
If required, remove the IEC line cord and
replace with an IEC AC cable that matches the AC
wall socket, this should be a 10A rated cable. When
the voltage selector switch is changed, the fuse
must also be changed to continue to provide
protection to the amplifier.
8.
Power Cord Receptacle:
The supplied power
cord needs to be connected to this receptacle in
order for the amplifier to work properly.
9.
Fuse Holder:
This is the power fuse access.
WARNING!
In the event the fuse must be replaced,
the replacement fuse must match exactly the
original fuse value or damage to the amplifier may
result.
Use a 8A 120V or 4A 240V fuse.
CAUTION!
Before replacing the fuse, disconnect
the power cord from the power receptacle.
10.
Removable Feet:
The amplifier feet can be
removed as required for rack mount installation.
Control Flow Chart - SUB Mode
Remote Control
REMOVE FUSE HOLDER HERE
NOTE: A spare fuse is also
located in this holder
10MM
(±2.0)
20MM
(±0.5)
5.2MM
(+0.1/-0.2)
Subsonic/ Freq.
Presets
Crossover/ Freq.
Auto Off
Phase
Lock Setting
Memory Store
Memory Recall
Mode select
Normal
Night Mode
External Trigger
Crossover/ Slope
Normal
OSD
Time Out
Volume
0,-1,-2,-3,-5,-6,-7,-9,-11,-13,
-15,-17,-19,-23,-27,-31,-35,
-39,-43,-49,-55,-61,-67,-73,
-79,
FLAT, 16, 20, 25, 31, or 40 Hz
40 ~ 160 Hz
6, 12, 18, 24, 30, 36, or 48 dB
Preset 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
0°, 45°, 90°, 135°, 180°, 225°, 270°, or 315°
Disable, Enable
Disable, 5, 10, 15, 20, 25, or 30 min
SUB, LFE (bypass LPF)
Off, On
Disable, Enable
Mem1, Mem2, or Mem3
Mem1, Mem2, Mem3, or Default
Function
Name
Adjust
Value
Left Turn
Right Turn
Enter Key
TRU-S500DSP
STORE
1
STORE
2
STORE
3
RECALL
1
RECALL
2
RECALL
3
Power ON
Scroll Right
Exit
Night OFF
Menu/Enter
Power OFF
Volume Up/
Scroll Up
Scroll Left
Mute
Memory
Recall Memory
Flat
Night ON
Volume Down/
Scroll Down