10. CREATE A TEMPORARY CODE

Temporary access for house sitter, contractor, cleaning company, etc. Use one of the 50 
available User Codes       and give it out for temporary access and delete it when it is no 
longer required. See steps 3 and 4 on page 13.  

11. RESTORE TO FACTORY SETTINGS

 (Make sure latch is retracted - unlocked) 

To reset the lock to the original factory settings including the Programming Code 
and all User Codes       remove one battery for 10 seconds. Reinsert the battery, hear a long 
and short beep, then immediately press       3 times within 3 seconds. The lock will 
beep and the light indicator will turn green.

12. VACATION MODE

With Vacation Mode enabled, the system enters into low-power consumption mode. During 
this mode, all buttons and functions including the remote control will be invalid until they are 
re-enabled (see steps below).

Enable:

Hear 1 beep and Light Indicator illuminates green then lock door

Disable:

To disable the Vacation Mode, you must press and hold        for more than 3 seconds, then 
input        to unlock the door. Vacation Mode is now disabled.

NOTE:

 If you only press the        for more than 3 seconds but do not input        the system 

will remain in Vacation Mode.

Attention:

When battery is under low voltage, the lock will give the (Low Battery Warning: Beeps and LED 
flashes red for 5 seconds). During this time your lock can still work. However once the voltage is lower 
than 4.3V (called Super-Low Voltage), the operation of the locking and unlocking will not work, user 
must replace batteries immediately. 

Audio and Visual Message Guide

Unlock / Valid programming:

Lock:

Invalid Programming:

Low Voltage:

Super Low Voltage:

4 Incorrect code entry attempts:

Power on:

Chip Reset:

Lock Error:

Repeat operation after Lock Error: 

1 long beep and LED illuminates green

2 short beeps and LED illuminates red

2 short beeps and LED flashes red twice

Beeps for 5 seconds (7/9 times depends on operation is unlock/lock)

4 short beeps and LED flashes red four times

2 short beeps and LED illuminates red each attempt

1 long beep and 1 short beep and LED illuminates green 

1 long beep and 1 short beep and LED illuminates green (may occur several times or once in a while)

3 long beeps LED flashes red three times

2 short beeps three times LED flashes red six times

UC

PC

UC

PC

10

PC

PC

1

Summary of Contents for 0711016

Page 1: ...Page 1 0711016 ...

Page 2: ... 2ea Screw D 1ea Deadbolt Strike Plate latch 2 3 4 latch 2 3 8 Do NOT use electric screwdriver only hand tighten screws with phillips head screwdriver DO NOT OVER TIGHTEN SCREWS Cylindrical cover Extension plate Your latch is now set 2 3 8 60mm backset 2 3 4 70mm 2 3 8 60mm Cylindrical cover Extension plat 2 3 4 70mm ...

Page 3: ...hten screws Note for drive in latch DRILL HOLE size indicated on template and PRESS latch until it is flush with door edge a Drill 2 1 8 hole through door face as marked for lock set b Drill 1 hole in center of door edge for latch 1 a 1 b 2 a 2 b I N S TA L L AT I O N I N S T R U C T I O N S DRILLING HOLE IN DOOR 4 INSTALL DEADBOLT STRIKE PLATE a Mark template from edge of jamb and locate strike o...

Page 4: ...sion plate all the way out d Rotate the cylinder cover counter clockwise so that the marking aligns with the 2 3 4 position indicator Measure the backset Backset is Distance between edge of the door and the center of Lock To convert from 2 3 8 60mm backset to 2 3 4 70 mm backset I N S TA L L AT I O N I N S T R U C T I O N S GETTING STARTED For troubleshooting tips and how to videos visit www trubo...

Page 5: ... cylinder cover Clockwise c Push and twist the extension plate all the way in d Rotate the cylinder cover counter clockwise so that the marking aligns with the 2 3 8 position indicator 2 TO CONVERT FROM 2 3 4 70 MM BACKSET TO 2 3 8 60MM BACKSET fig 1 Cylindrical cover Extension plate Your latch is now set 2 3 8 60mm backset 2 3 4 70mm 2 3 8 60mm fig 2 NOTE Do not extend Cylindrical Cover past 2 3 ...

Page 6: ...Swing Door In Swing Door fig 5 4 Deadbolt Latch must be retracted when installing a Insert Deadbolt Latch into door edge hole with the word UP and the arrow on the extension plate facing UP Cross shaped spindle connector will be at the bottom of the Deadbolt Latch b Make sure the face plate sits flush with the door Do not force the latch into the mortise flush Chisel out excess material if necessa...

Page 7: ...gular slot in the Mounting Plate b Place Mounting Plate against door with tailpiece passing through the center hole in the three holeset c Secure the Mounting Plate to the Exterior Assembly using Screw B 2 ea d Hand tighten with a screwdriver leaving loosely connected e Check that the Rubber Gasket is properly aligned and correct as necessary f Check vertical alignment of the lock g Tighten with a...

Page 8: ...ng the Mounting Plate upper hole as a guide see Figure 8a b Insert Screw A and tighten 8 OPTIONAL INSTALLATION 8 NOTE LOCK AND UNLOCK USING THE KEY TO SEE IF THE DEADBOLT LATCH IS OPENING AND CLOSING EASILY Entry Switch Left or Right fig 9 Right Handed Door Hinges are on the right side Left Handed Door Hinges are on the left side Right Handed Door Hinges are on the right side Left Handed Door Hing...

Page 9: ... the HORIZONTAL position for Left Handed Doors 11 ATTACH THE CONTROL WIRE TO THE INTERIOR ASSEMBLY 10 SET THE INTERIOR KNOB POSITION FOR LEFT OR RIGHT HANDED DOORS 12 Position the Interior Assembly over the tailpiece and push the Interior Assembly against the door 13 Using Screw C 2 ea and Screw D 1 ea attach the Interior Assembly to the Mounting DO NOT OVER TIGHTEN SCREWS Screws C Screw D Screw D...

Page 10: ...n into the track on the Interior Assembly to cover the batteries 16 With the Door Open a Test the Lock using the interior turn piece bolt should move smoothly b Test the lock using the Keypad to lock press and then press 1234 to unlock Interior Door Face Thumbturn Knob Battery Cover Light Indicator Override Access Key Exterior Door Face Keypad Lewis Hyman Inc Customer Service 1 800 860 1677 fig 14...

Page 11: ...verify that the tailpiece is vertical Lock will not function electronically Check that all batteries are fresh high quality Alkaline Batteries Check for proper polarity of all batteries Check that the Control Wire is attached to the Interior Assembly Lock gives error signal when opening or locking and deadbolt will not extend or retract completely when door is closed Unlock door using key or inter...

Page 12: ...C PC ID UC Factory Settings new The lock comes factory preset with a Programing Code 123456 User Code 1234 User ID 01 Please change the Programming Code and User Code as soon as possible after installation to ensure security UC ID PC UC PC Electronic lock requires 4 High Quality AA Alkaline batteries When all 4 batteries are installed in the correct position hear 2 beeps and the keypad will illumi...

Page 13: ...e is then linked to a User ID which is any number between 01 50 to identify an individual User Code User ID 1 9 should be entered as 01 09 so they are 2 digits For example to add the User ID 08 to User Code 5678 enter the following Hear 1 beep and Light Indicator illuminates green NOTE When a NEW USER CODE is set the default factory code 1234 is deleted for safety 5 DELETE ONE EXISTING OR PRESET U...

Page 14: ...tes green To cancel Auto Lock set the time to 00 enter the following Cancel Time Value Auto Lock Hear 1 beep and Light Indicator illuminates green 8 TEMPORARILY DISABLE AUTO LOCK Disable While in Auto Lock mode unlock door using within 10 seconds you must turn the locking knob by hand to the locked position wait more than 2 seconds then turn the locking knob back to the unlock position The Auto Lo...

Page 15: ...ation Mode is now disabled NOTE If you only press the for more than 3 seconds but do not input the system will remain in Vacation Mode Attention When battery is under low voltage the lock will give the Low Battery Warning Beeps and LED flashes red for 5 seconds During this time your lock can still work However once the voltage is lower than 4 3V called Super Low Voltage the operation of the lockin...

Page 16: ...ing and freight expenses required to return product s to nearest Menards retail store In no event shall Tru Bolt be liable for any special incidental or consequential damages Customers will receive instructions as to the disposition of the defective item s Menards reserves the rights which may vary from state to state If this product s is considered a consumer product please be advised that some l...

Page 17: ...ACE TEMPLATE ON HIGH EDGE OF DOOR BEVEL THEN DRILL 1 25mm HOLE IN CENTER OF DOOR EDGE 2 IN DEPTH FOLD HERE ON DOOR EDGE 2 8 BACKSET 3 MARK FOR 1 45mm DOOR 3 4 DRILL 2 1 8 54mm HOLE MARK CENTER OF HOLE ON DOOR FACE TEMPLATE 2 4 BACKSET 3 3 8 MARK FOR 1 35mm DOOR ...

Reviews: